2153 002
Process Control
*EGB
Enables or disables the adjustment after
process control is done.
[0 or 1 / 1 / -] Alphanumeric
0: Off, 1: On
2153 003
Initialization
*EGB
Enables or disables the adjustment immediately
after the power is turned on or when recovering
from energy save mode.
[0 or 1 / 1 / -] Alphanumeric
0: Off, 1: On
2153 004
Data In
*EGB
Enables or disables the adjustment immediately
after the machine starts to receive print job data.
The adjustment is done if one of the conditions
set with SP2153-012, -013 and –015 is
satisfied.
[0 or 1 / 1 / -] Alphanumeric
0: Off, 1: On
2153 005
Cut In
*EGB
Enables or disables the adjustment during
printing. The adjustment is done if one of the
conditions set with SP2153-012, -013 and –
015 is satisfied.
[0 or 1 / 1 / -] Alphanumeric
0: No, 1: Yes
2153 006
Job End
*EGB
Enables or disables the adjustment after
printing.
[0 or 1 / 0 / -] Alphanumeric
0: Off, 1: On
2153 008
Trans. Belt Speed 2
*EGB
Enables or disables the transfer belt speed
correction during the adjustment. The transfer
belt speed is affected by changes in
temperature. A change of the transfer belt
speed during the adjustment causes color
registration errors. This SP keeps the transfer
belt at a constant speed.
[0 or 1 / 1 / -] Alphanumeric
0: Off, 1: On
5. Service Tables
178
5
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...