Table 2-1. DC-200/300 (141) Settings
64
Scale A <–> B
Sets whether the unit weight determined by sampling on Scale A is automatically transferred to Scale
B or not.
0: Manual (DEFAULT)
1: Auto
65
Unit of Pcs Weight
Sets whether the unit weights are displayed per 1000 pieces or per 1 piece. For a further discussion of
the benefits of each option, please see Section 5.4.
0: 1000 pieces (DEFAULT)
1: 1 piece
66
Not used
67
IMS
Determines whether or not the scale automatically queries the DIGI Inventory Management Software
(IMS) for all of the parameters associated with an Item Code when the
CODE
key is pressed. For
more information on this option, please see Section 6.3.1.
0: Disable (DEFAULT)
1: Enable
68
EPSON II
Changes the Epson label format from the default (all item information fields) to an abbreviated format
with only selected fields.
0: Disable (DEFAULT)
1: Enable
69
4 Lot No.
If disabled, allows a single lot number to be entered during weighing operations. If enabled, allows up
to 4 lot numbers to be entered. These lot numbers are not written to the item database.
0: Disable (DEFAULT)
1: Enable
70
Upload Lot and Part Number
If disabled, lot numbers and part numbers entered during weighing operations are not uploaded to the
item database. If enabled, lot numbers and part numbers entered during weighing operations
overwrite the information previously stored with the item code in the scale memory.
0: Disable (DEFAULT)
1: Enable
71
Text 11-16 TTL
Allows you to use text fields 11-16 on total labels rather than just item labels.
0: Disable (DEFAULT)
1: Enable