the procedure is taking place.
7. Once the settings are reinitialized, the scale will go through its normal start-up segment check and then
return to the Span Switch On Mode.
2.6
Start-Up Screens
The instructions below assume that you are using the scale as a stand-alone unit, with or without remote
platforms. For information on using the DC-200/300 as a network workstation, see Section 6.0.
1. As the scale powers up it will display the current version of the firmware it is using. It also shows that the
scale is currently being operated as a stand-alone unit.
2. After a test of the different elements of the display, the scale takes you to the stand-by screen in the
Operation Mode. At the stand-by screen the
WEIGHT, UNIT WEIGHT
and
QUANTITY
displays show zeroes
and the annuciator for the platform you are using is illuminated (A, B, C or D).
From this stand-by screen all of the basic weighing, counting and inventory operations can be performed
(See Section 6.0 on page 77). Also, if any job sequence instructions have been programmed into the
scale, the first operator instruction will be displayed on the second line of the display (Section 8.0).
3. If there is anything on the platform(s) and it exceeds the scale start range, a beep sounds, and the
following error message appears.
Note:
The Initial Start Range settings are controlled by SPEC 631. The default setting is 0: +UNLIMITED TO 10%
OF FULL SCALE.
Remove the weight from the platform and press the
CLEAR
key to exit.