SPEC
Description
00
Auto Power Saving When No Weight Change & No Key Press
0: Disable (DEFAULT)
1: 1 minute
2: 2 minutes
3: 3 minutes
4: 4 minutes
5: 5 minutes
6: 6 minutes
7: 7 minutes
8: 8 minutes
9: 9 minutes
10: 10 minutes
11: 11 minutes
12: 12 minutes
13: 13 minutes
14: 14 minutes
15: 15 minutes
01
Power Saving Type
When set to 0, the backlight turns off when the scale goes into power-saving mode. When set to 1,
the scale turns off entirely
0: Backlight Off (DEFAULT)
1: Power Off
02
Negative Counting
0: No
1: Yes (DEFAULT)
03
Extent of Insufficient Samples
Sets the percentage of the full scale capacity that the initial counting sample has to exceed, otherwise
the
INSUFF
lamp lights.
0: 0.1% (DEFAULT)
1: 0.2%
2: 0.0%
04
Set New Item Code During Registration (Operation) Mode
0: Yes (DEFAULT)
1: No
05
Date Order
0: Month/Day/Year (DEFAULT)
1: Day/Month/Year
2: Year/Month/Day
06
Time Format
0: 24 hour (DEFAULT)
1: 12 HOUR (am/pm)
07
Unit Weight Auto Recomputing
0: No (DEFAULT)
1: Yes
08
Sampling Times for Unit Weight Calculation
Higher number samples improve accuracy in environments of higher vibration or breeze but also
increase the time required to compute the unit weight.
0: 15 times (DEFAULT)
1: 20 times
09
Display Accuracy Unit Weight Calculation During Recomputing
0: No (DEFAULT)
1: Yes
All manuals and user guides at all-guides.com