background image

*859.715
*859.725 
*859.735

Summary of Contents for 859.715

Page 1: ... 859 715 859 725 859 735 ...

Page 2: ...859715 25 35 en ma 2012 07 ...

Page 3: ... Subtractionfunction 18 7 USER PROGRAMMINGFUNCTIONS 19 7 1 Backlight type 19 7 2 RS 232 transmission method 19 7 3 Labelformatsetting 20 7 4 Baud Rate setting 21 7 5 RS 232 transmission method in accumulation mode 21 7 6 Zero tracking range 22 7 7Stable classrange 22 7 8 Selection of the availableunits 23 8 BATTERYOPERATION 24 9 RS 232 OUTPUT 25 10 AUTO CALIBRATION 33 11 RECOVERYOFTHEDEFAULTCALIBR...

Page 4: ... 4 1 PRECAUTION BEFORE USING THE SCALE 859715 25 35 en ma 2012 07 ...

Page 5: ...5 859715 25 35 en ma 2012 07 ...

Page 6: ... the platform The switch is located at the bottom of the right side of the scale The scale will start to count down from nine to zero Then the scale is ready for use Give a warm up for 15 30 minutes before use 2 INTRODUCTION The precision electronic weighing scale offers a range of capacities from 3 kg to 30kg The scales are very simple to use and applicable for general weighing The user can also ...

Page 7: ...pply ACAdaptor12V 800mA Display 6 digits LCD digital display Pan Size mm inch 306 W x 222 D 12 0 W x 8 7 D Functions Weighing Counting pieces Percentage Check weighing Check counting Check percentage Accumulation summing Other Features and Specs Internal rechargeable battery 859715 25 35 en ma 2012 07 ...

Page 8: ... 8 4 DISPLAYS The LCD display will show a value and a unit to the right of the digits Other labels are TARE GROSS weight ZERO stable and for Low battery 859715 25 35 en ma 2012 07 ...

Page 9: ...ameters or other functions Be used to select the functions of the scale If the scale is in weighing mode it will select parts counting Of it is not in weighing mode it will return the user to weighing A secondary function Ÿ increment the active digit when setting values for parameters or other functions Print the results to a PC or a printer by using the optional RS 232 interface It also adds the ...

Page 10: ... 10 859715 25 35 en ma 2012 07 ...

Page 11: ...nts of weight are shown when the platform is empty Note Zeroing function is possible to operate only when the scale is stable with 6 2 Unit selection You can choose the desired unit by pressing UNIT Clear key The display will cycle through the options g kg lb oz and back to g 6 3 Taring Before Tare function is used if zeroing the scale is needed press the ZERO key Then the indicator of zero will b...

Page 12: ...d Ɣ Press TARE Enter key again to enter into the normal weighing mode and the negative value will disappear Note Taring function is possible to operate only when the scale is stable with 6 4 Percentage This mode shows the proportion of standard weight Astandard weight is selected whatever you want within max capacity of the scale When you place a sample on the container the display shows the perce...

Page 13: ... however a small change of weight will cause the display to jump to 100 13 6 5 Counting pieces Before beginning if you want to use any container use Tare function first Ɣ Place samples ex 200g as 10pcs on the pan The number of samples should match the options for parts counting 10 20 50 100 200 500 or 1000 pieces Ɣ Press the COUNT key to begin Then the display will show SP10 To change the number o...

Page 14: ...a low limit Either limit can be used or both can be used This function is available in weighing counting pieces and percentage Ɣ Press the CHECK key The display will show the current High Limit with the left most digit flashing and the HI symbol on the left of the display Ɣ Input high limit value The location of flashing digit is possible to move as CHECK and key The real value from 0 to 9 is poss...

Page 15: ...e scale the arrows will show if the weight is above or below the limits and the beeper will sound as described below BOTH LIMITS SET The display will show OK and the beeper will sound when the weight is between the limits LOW LIMIT SET Ɣ HIGH LIMIT is set to zero Ɣ The display will show OK and the beeper will sound when the weight is less than the Low Limit ƔAbove the Low Limit the display will sh...

Page 16: ...ng to operate 4 To disable the Check weighing function enter zero into both limits by pressing the CHECK key to recall the current settings Pressing UNIT Clear key when the current limits are shown to clear the settings then pressing the TARE Enter key to store the zero values 6 7 Hold function When weighing an active thing press HOLD key to hold the display to read the value easily and clearly Pl...

Page 17: ... total weight is displayed for about 2 seconds Then the scale returns to normal weighing mode 4 Remove all weights from the pan in order to zero the scale Place the second weight on the pan ex 500g 5 Press M Exit key to add the second weight then is displayed for a few seconds 6 After showing of the total weight is displayed for about 2 seconds Then the scale returns to normal weighing mode 859715...

Page 18: ...232 transmission method in accumulation mode Please refer to section 7 5 7 When the present weight is less than 10d and press M Exit key The scale can t store this value in memory but only display total accumulated values and times 6 9 Subtraction function Use UNIT Clear key to subtract accumulation values This function is available only in accumulation mode Ɣ Nothing on the pan If you make a mist...

Page 19: ...ically whenever the scale is loaded by objects weigh greater than 9 display resolution or any of keys is pressed And it will be going off also automatically approx 5 seconds after the scale returns to zero ELoff Backlight OFF Backlight always is OFF Note The maximum battery life is achieved with the backlight turned off Press the TARE Enter key in order to confirm and move to next setting 7 2 RS 2...

Page 20: ...s on the scale Press the PRINT key to print the total data in bar code ex DLP 50 label printer PCont Series transmit OFF None data is transmitted When the scale receives specific request from peripheral device the scale will send weight data to peripheral device Note 1 When Gross weight is Negative Value Output is not be transmitted by pressing PRINT key But in series transmission negative value c...

Page 21: ...are 2 options You can select its options by pressing COUNT key Please refer to section 9 4 Options ACp on ACp off Default setting ACp on ACP on When pressing M Exit key in order to add a data an each of added data weight or count will be transmitted and printed out Also when pressing PRINT key the total value will be transmitted ACPof When pressing M Exit key in order to add a data an each of adde...

Page 22: ...ter key in order to confirm and move to next setting 7 7 Stable class range There are 3 options for stable class range You can select its options by pressing COUNT key Options 0 0 1 0 3d 2 0 6d 3 0 9d Default value 1 0 3d Press the TARE Enter key in order to confirm and move to next setting Note The smaller number is the shorter time for display stability 859715 25 35 en ma 2012 07 ...

Page 23: ...OUNT key to set ON or OFF After set each of unit ON or OFF press TARE Enter key to confirm and move to next unit selection After setting the last unit oz press TARE Enter key to go back to normal weighing mode NOTE 1 Aunit can not be exchanged in counting mode or when tare function performed 2 In accumulation mode or check weighing setting is available give a long press of UNIT Clear key to exchan...

Page 24: ... module to the scale and plug in The scale does not need to be turned on The battery should be charged for 12 hours for full capacity There is an LED to indicate the status of battery charging on the right of display When the scale is plugged into the mains power the internal battery will be charged Green The battery has been charged Red The battery is nearly discharged As the battery is used it m...

Page 25: ... Pin3 Output Pin5 SignalGround 9 3 Transmit format Au on off DEP 50 form Au off Ɣ ACP is set to be on then press M Exit key to output each accumulated value Press PRINT key to transmit total accumulated values and accumulated times Please refer to the section 7 5 Weighing mode WEIGHT Weight 100 0g Weight 100 0g Weight 100 0g Weight 99 9g Weight 100 0g Weight 13 8g Weight 100 0g Weight 100 0g Total...

Page 26: ...countisnot 0 thecount ofresultswillbe 0 Takeweighingmodeforinstance Weighingmode WEIGHT Weight 150g Weight 400g Weight 550g Total 0g Count 0times When total weight pcs ismore than 0 andrealcount times is 0 the resultsofcount timeswon tbe 0 Forexample Countingmode WEIGHT Quantity 90pcs Quantity 56pcs Quantity 90pcs Quantity 56pcs Total 68pcs Count 1times 859715 25 35 en ma 2012 07 ...

Page 27: ...s Ɣ When the accumulation is not used and limit values are not set press PRINT key to transmit the value showing in display window Weighing mode Weighing Function WEIGHT Weight 90 g Tare 20 g Gross 110 g Counting mode Counting Function COUNT Weight 174 g U Weight 9 04 g Quantity 19 pcs Tare 29 g Gross 205 g Percentage mode Percentage Function PERCENT Weight 176 g Percent 95 02 Tare 28 g Gross 204 ...

Page 28: ... 28 Ɣ When the Accumulation function is not used and the limit values are set And transmit by pressing PRINT key Weighing mode Counting mode Percentage mode 859715 25 35 en ma 2012 07 ...

Page 29: ...g Weight 90g Countingmode Quantity 10pcs Quantity 34pcs Quantity 50pcs Percentagemode Percent 21 33 Percent 51 04 Percent 27 62 9 4 Format P cont series transmission HEAD1 2BYTES HEAD2 2BYTES OL Overload NT NETMode ST DisplayisStable GS GrossWeight US DisplayisUnstable DATA 8BYTES 2D HEX MINUS 20 HEX SPACE 2E HEX DECIMALPOINT UNIT 4BYTE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 HEAD1 HEAD...

Page 30: ...8lb whenitisunstableandnetvalueas HEAD HEAD DATA UNIT CR US NT 1 568 lb 0D0A EX whenitisoverloadedandnetvalueas HEAD HEAD DATA UNIT CR OL NT oz 0D0A 9 6 Format OFF When the scale receives specific request from peripheral device the scale will send weight data to peripheral device ENQ 05H EOT 04H ACK 06H DC1 11H NAK 15H SOH 01H STX 02H ETX 03H DC1 11H SOH STX STA SIGN W6 W5 W4 W3 W2 W1 W0 UN1 UN0 B...

Page 31: ...n of the weight data Zero and positive weight negative weight Overload F W6 through W0 weight data But all F s when the scale is put on overload UN1 through UN0 unit of weight kg or Ib 9 7 DLP 50 Print out Format with EAN13 barcode 9 8 The wire connections 859715 25 35 en ma 2012 07 ...

Page 32: ...K key 0x43 C c 0x63 Same as COUNT Ÿ Key 0x52 R r 0x72 Same as Key 0x55 U u 0x75 Same as UNIT CLEAR Key 0x4D M m 0x6D Same as M Exit key 0x50 P p 0x70 Same as PRINT Key 0x5A Z z 0x7A Same as ZERO Key 0x54 T t 0x74 Same as TARE ENTER Key 0x48 H h 0x68 Same as HOLD Key 859715 25 35 en ma 2012 07 ...

Page 33: ...hed By pressing the COUNT key the weight value can be selected 1 3 Full weight 2 3 Full weight and 3 3 Full weight This calibration instruction is NOT for US market 11 RECOVERY OF THE DEFAULT CALIBRATION VALUE FROM MEMORY When a mistake is happened during calibration or parameter is set incorrectly this function should be useful Operation Turning on the scale press the TARE TARE COUNT COUNT COUNT ...

Page 34: ... Tareweight nodot 6byte TWP Weighing RightshiftingdigitofTWB 1byte GWA Weighing counting percent Grossweight 7byte GWB Weighing counting percent Grossweight nodot 6byte GWP Weighing RightshiftingdigitofGWB 1byte TNA Weighing Totalnetweight 7byte TNB Weighing Totalnetweight nodot 6byte TNP Weighing RightshiftingdigitofTNB 1byte TTA Weighing TotalTareweight 7byte TTB Weighing TotalTareweight nodot 6...

Page 35: ...g counting percent LowLimit 7byte CLB Weighing counting percent LowLimit nodot 6byte UNT Weighing counting percent WeighingUnit 2byte UWU Weighing counting percent Weighingunitincountingmode 2byte Note 1 P variable The weight accumulation value exceeds 6 digits but it can achieve 6 digit display through righting decimal point One or two digits behinds the decimal point won t display after being ro...

Page 36: ...g 15kg x0 5g 30kg x1g g 3 0009 6 0018 15 0045 30 009 Ib 6 0018 15 0045 30 009 60 018 oz 105 045 210 09 520 18 1050 45 ERRORCODE POSSIBLECAUSES HANDLING E1 EPROMdatalose Re calibratethescale 1 Loadcelldamaged 1 Replacetheloadcell E2 2 Turnonthescalewith somethingonthepan 2 Correcttheoperation E3 The sample weight for setting up Percent weighing is much less than theweightonthepan Correcttheoperatio...

Page 37: ...hAlertbeeper WeightUnits Kg g lb oz ZeroRange 2 TareRange FullCapacitybySubtraction StabilizationTime 2seconds OperationTemperature 0 40 32 104 HumidityRange 90 relativehumidity non condensing Power ACAdaptor12V 800mA Internalrechargeablesealedacidbattery BatteryLife 80hourscontinuoususewith12hourrechargetime Calibration Automaticexternalwithg Ibmass factorycalibrationrecovery SafeOverloadCapacity...

Reviews: