System design
2-17
350 (13.78)
325 (12.8)
293 (11.54)
133.5
(5.26)
42 (1.65)
2.6 RCU10 component mounting
2.6.1
RCU10-XX-XX or RCU10-PX-XX
The RCU10 is intended to be mounted in an electrical control cabinet or similar
environment. It is constructed with IP40 protection and therefore needs to be protected
from harsh environmental conditions.
The RCU10 may be mounted in any orientation, although the status display window is
intended to be read with the unit vertical (display window to the top).
If the RCU10-P is to be contained in a sealed enclosure, it will be necessary to port the
pressure sensor aperture to the outside environment such that the correct air pressure is
measured. This can be done by using 4 mm O.D. plastic tubing which will simply push fit
into the aperture. To remove the plastic tube, push the collet towards the connector whilst
pulling the tube.
Figure 2.13 – RCU10 dimensions
For connector/cable clearance purposes, allow 100 mm (4 in) from the front face of the
RCU10. Additionally, if a multi-axis system is being installed, allow 100 mm (4 in) from the
top face of the unit for the high-speed serial link cables.
Note:
Using the fixings supplied with the unit (M4 x 5 cap head 4 mm plain
washers) ensures that earthing is achieved directly through the brackets.
Mounting holes
7 mm x 9.5 mm
Dimensions in
mm (in)
Summary of Contents for RCU10
Page 1: ...Installation and user s guide M 9904 1122 09 A RCU10 quadrature compensation unit...
Page 11: ...viii Contents This page is intentionally left blank...
Page 23: ...1 12 System overview This page is intentionally left blank...
Page 39: ...2 16 System design...
Page 49: ...3 6 Kit configuration and part identification This page is intentionally left blank...
Page 67: ...4 18 System installation This page is intentionally left blank...
Page 91: ...A 6 RCU10 system specifications This page is intentionally left blank...
Page 147: ...E 8 Commissioning tests This page is intentionally left blank...
Page 175: ...F 28 Extended capability This page is intentionally left blank...
Page 189: ...G 14 Reference This page is intentionally left blank...
Page 193: ...H 4 Test records This page is intentionally left blank Cut here Cut here...
Page 195: ...H 6 Test records This page is intentionally left blank Cut here Cut here...