Compensation system status information and diagnostics
D-11
Table D.9 – Sensor status errors/warnings
Error
State Description
Corrective action (if necessary)
Out Of
Range
OFF
Sensor is operating within its normal range of
operation.
None required.
RED
Sensor is reading outside its normal
operating range.
Sensor failure.
Move sensor to a more suitable
environment.
Replace sensor.
Rate
Exceeded
OFF
Sensor is operating within its normal rate of
change.
None required.
RED
Sensor is changing value at a quicker rate
than its normal setting.
Sensor failure.
Move sensor to a more suitable
environment.
Replace sensor
Calibration
Failure
OFF
Sensor is operating within its calibrated
specification.
None required.
RED
Sensor data is out of calibration.
Return sensor to Renishaw for
recalibration.
Not Ready
OFF
Sensor is operating normally.
None required.
RED
Sensor’s operational accuracy is not ready.
Sensor is still initialising.
Wait for sensor to finish initialising
procedure.
Disconnect sensor, wait a few
seconds, and then reconnect sensor.
Internal
Error
OFF
Sensor is operating without error.
Sensor is operating with any number of the
above errors present (non-conflicting).
None required.
Check other sensor status error
conditions.
RED
More than one of the above errors occurring
simultaneously are conflicting.
Sensor failure.
Check other sensor status error
conditions.
Replace sensor
NOTE:
Sensor Status
and
Compensator Status
titles will display with a red or green
background depending upon whether an error/warning has been indicated.
Summary of Contents for RCU10
Page 1: ...Installation and user s guide M 9904 1122 09 A RCU10 quadrature compensation unit...
Page 11: ...viii Contents This page is intentionally left blank...
Page 23: ...1 12 System overview This page is intentionally left blank...
Page 39: ...2 16 System design...
Page 49: ...3 6 Kit configuration and part identification This page is intentionally left blank...
Page 67: ...4 18 System installation This page is intentionally left blank...
Page 91: ...A 6 RCU10 system specifications This page is intentionally left blank...
Page 147: ...E 8 Commissioning tests This page is intentionally left blank...
Page 175: ...F 28 Extended capability This page is intentionally left blank...
Page 189: ...G 14 Reference This page is intentionally left blank...
Page 193: ...H 4 Test records This page is intentionally left blank Cut here Cut here...
Page 195: ...H 6 Test records This page is intentionally left blank Cut here Cut here...