F-24
Extended capability
Error log codes
Below is a basic list of codes for reference. These will give a basic overview of the main
events occurring in each error log record. For a clearer description, open each log event
and press
View Status Bitfields
to view the status lights activated.
0x1
Configuration compare failed
0x2
Reserved
0x4
LUT error
0x8
UARTA access error
0x10
Input counter error
0x20
Output counter error
0x40
Quadrature lines disconnected (float)
0x80
Fast serial bus failure
0x100
Pressure sensor failure
0x200
Parameter set selection error
0x400
External input error
0x800
HS10 signal low warning
0x1000
Reserved
0x2000
Air temperature sensor failure
0x4000
Workpiece material temperature sensor failure
0x8000
Reserved
0x10000
UARTB error
0x20000
Air compensation failed/Encoder compensation failed
0x40000
Workpiece expansion compensation failed
0x80000
Structure expansion compensation failed
0x100000
Excessive compensation applied
0x200000
Fast serial bus data corruption
0x400000
Following limit warning exceeded
0x800000
Following error exceeded
0x1000000
Scale material temperature sensor failure
0x2000000
Reserved
0x4000000
Reserved
0x8000000
Reserved
0x10000000
RTC and NVRAM failure
0x20000000
Message queue overflow – too many messages
0x40000000
Error queue overflow – too many errors
0x80000000
Structure material temperature sensor failure
Summary of Contents for RCU10
Page 1: ...Installation and user s guide M 9904 1122 09 A RCU10 quadrature compensation unit...
Page 11: ...viii Contents This page is intentionally left blank...
Page 23: ...1 12 System overview This page is intentionally left blank...
Page 39: ...2 16 System design...
Page 49: ...3 6 Kit configuration and part identification This page is intentionally left blank...
Page 67: ...4 18 System installation This page is intentionally left blank...
Page 91: ...A 6 RCU10 system specifications This page is intentionally left blank...
Page 147: ...E 8 Commissioning tests This page is intentionally left blank...
Page 175: ...F 28 Extended capability This page is intentionally left blank...
Page 189: ...G 14 Reference This page is intentionally left blank...
Page 193: ...H 4 Test records This page is intentionally left blank Cut here Cut here...