Section 9 Timers
Rev. 6.00 Sep 12, 2006 page 227 of 526
REJ09B0326-0600
Compare Match Flag set Timing:
Compare match flag A or B (CMFA or CMFB) is set to 1
when TCNTV matches TCORA or TCORB. The internal compare-match signal is generated in the
last state in which the values match (when TCNTV changes from the matching value to a new
value). Accordingly, when TCNTV matches TCORA or TCORB, the compare match signal is not
generated until the next clock input to TCNTV. Figure 9.7 shows the timing.
TCORA or
TCORB
φ
Compare
match signal
TCNTV
N
N
N + 1
CMFA or
CMFB
Figure 9.7 CMFA and CMFB Set Timing
TMOV Output Timing:
The TMOV output responds to compare match A or B by remaining
unchanged, changing to 0, changing to 1, or toggling, as selected by bits OS3 to OS0 in TCSRV.
Figure 9.8 shows the timing when the output is toggled by compare match A.
Timer V
output pin
φ
Compare
match A
signal
Figure 9.8 TMOV Output Timing
Summary of Contents for F-ZTAT H8/3642A Series
Page 6: ...Rev 6 00 Sep 12 2006 page iv of xx ...
Page 8: ...Rev 6 00 Sep 12 2006 page vi of xx ...
Page 22: ...Rev 6 00 Sep 12 2006 page xx of xx ...
Page 124: ...Section 5 Power Down Modes Rev 6 00 Sep 12 2006 page 102 of 526 REJ09B0326 0600 ...
Page 188: ...Section 6 ROM Rev 6 00 Sep 12 2006 page 166 of 526 REJ09B0326 0600 ...
Page 190: ...Section 7 RAM Rev 6 00 Sep 12 2006 page 168 of 526 REJ09B0326 0600 ...
Page 298: ...Section 9 Timers Rev 6 00 Sep 12 2006 page 276 of 526 REJ09B0326 0600 ...
Page 378: ...Section 12 A D Converter Rev 6 00 Sep 12 2006 page 356 of 526 REJ09B0326 0600 ...
Page 446: ...Section 13 Electrical Characteristics Rev 6 00 Sep 12 2006 page 424 of 526 REJ09B0326 0600 ...