Section 6 ROM
Rev. 6.00 Sep 12, 2006 page 128 of 526
REJ09B0326-0600
6.7.2 Program-Verify
Mode
In program-verify mode, the data written in program mode is read to check whether it has been
correctly written in the flash memory.
After the elapse of the programming time, exit programming mode (clear the P bit to 0) and select
program-verify mode (set the PV bit to 1). In program-verify mode, a program-verify voltage is
applied to the memory cells at the latched address. If the flash memory is read in this state, the
data at the latched address will be read. After selecting program-verify mode, wait at least 4 µs
before reading, then compare the programmed data with the verify data. If they agree, exit
program-verify mode and program the next address. If they do not agree, select program mode
again and repeat the same program and program-verify sequence. Do not repeat the program and
program-verify sequence more than six times* for the same bit.
Note: * When a bit is programmed repeatedly, set a loop counter so that the total programming
time will not exceed 1 ms.
Summary of Contents for F-ZTAT H8/3642A Series
Page 6: ...Rev 6 00 Sep 12 2006 page iv of xx ...
Page 8: ...Rev 6 00 Sep 12 2006 page vi of xx ...
Page 22: ...Rev 6 00 Sep 12 2006 page xx of xx ...
Page 124: ...Section 5 Power Down Modes Rev 6 00 Sep 12 2006 page 102 of 526 REJ09B0326 0600 ...
Page 188: ...Section 6 ROM Rev 6 00 Sep 12 2006 page 166 of 526 REJ09B0326 0600 ...
Page 190: ...Section 7 RAM Rev 6 00 Sep 12 2006 page 168 of 526 REJ09B0326 0600 ...
Page 298: ...Section 9 Timers Rev 6 00 Sep 12 2006 page 276 of 526 REJ09B0326 0600 ...
Page 378: ...Section 12 A D Converter Rev 6 00 Sep 12 2006 page 356 of 526 REJ09B0326 0600 ...
Page 446: ...Section 13 Electrical Characteristics Rev 6 00 Sep 12 2006 page 424 of 526 REJ09B0326 0600 ...