Section 6 ROM
Rev. 6.00 Sep 12, 2006 page 164 of 526
REJ09B0326-0600
the 0 or 1 status of this bit. A byte data comparison is necessary to check whether 12V is
being applied. The relevant coding is shown below.
.
.
LABEL1: MOV.B @H'FF80, R1L
CMP.B #H'FF, R1L
BEQ LABEL1
.
.
.
Sample program for detection of 12 V application to FV
PP
(user
mode)
Table 6.17 Flash Memory DC Characteristics
V
CC =
3.0 V to 5.5 V, AV
CC =
3.0 V to 5.5 V, AV
REF =
3.0 V to AV
CC
, V
SS
= AV
SS
= 0 V,
V
PP
= 12.0 V ±0.6 V
T
a
= –20°C to +75°C (regular specifications), T
a
= –40°C to +85°C (wide-range specifications)
Item
Symbol
Min
Typ
Max
Unit
Test
Conditions
High voltage (12 V)
application criterion
level
*
FV
PP
, TEST
V
H
V
CC
+ 2
11.4
V
FV
PP
current
Read
I
PP
10 µA
V
PP
= 2.7 to 5.5 V
10 20 mA
V
PP
= 12.6 V
Program
20 40 mA
Erase
20 40 mA
Note:
*
The high voltage application criterion level is as shown in the table above, but a setting
of 12.0 V ±0.6 V should be made in boot mode and when programming and erasing
flash memory.
Summary of Contents for F-ZTAT H8/3642A Series
Page 6: ...Rev 6 00 Sep 12 2006 page iv of xx ...
Page 8: ...Rev 6 00 Sep 12 2006 page vi of xx ...
Page 22: ...Rev 6 00 Sep 12 2006 page xx of xx ...
Page 124: ...Section 5 Power Down Modes Rev 6 00 Sep 12 2006 page 102 of 526 REJ09B0326 0600 ...
Page 188: ...Section 6 ROM Rev 6 00 Sep 12 2006 page 166 of 526 REJ09B0326 0600 ...
Page 190: ...Section 7 RAM Rev 6 00 Sep 12 2006 page 168 of 526 REJ09B0326 0600 ...
Page 298: ...Section 9 Timers Rev 6 00 Sep 12 2006 page 276 of 526 REJ09B0326 0600 ...
Page 378: ...Section 12 A D Converter Rev 6 00 Sep 12 2006 page 356 of 526 REJ09B0326 0600 ...
Page 446: ...Section 13 Electrical Characteristics Rev 6 00 Sep 12 2006 page 424 of 526 REJ09B0326 0600 ...