9 Settings
9.1
Description of the user level parameters
Tab.25 Factory settings
Parameter
Text display
Adjustment range
160
AP016
Enable or disable central heating heatdemand
processing
0 = Off
1 = On
1
AP017
Enable or disable domestic hot water heatdemand
processing
0 = Off
1 = On
1
AP081
Shortname of the device
CU6
CP080
User Room Setpoint Zone Activity temperature
5 °C - 30 °C
16
CP081
User Room Setpoint Zone Activity temperature
5 °C - 30 °C
20
CP082
User Room Setpoint Zone Activity temperature
5 °C - 30 °C
6
CP083
User Room Setpoint Zone Activity temperature
5 °C - 30 °C
21
CP084
User Room Setpoint Zone Activity temperature
5 °C - 30 °C
22
CP085
User Room Setpoint Zone Activity temperature
5 °C - 30 °C
20
CP320
Operating mode of the zone
0 = Scheduling
1 = Manual
2 = Antifrost
3 = Temporary
1
CP550
Fire Place mode is active
0 = Off
1 = On
0
CP570
Time Program of the zone selected by the user
0 = Schedule 1
1 = Schedule 2
2 = Schedule 3
3 = Cooling
0
CP660
Choice icon to display this zone
0 = None
1 = All
2 = Bedroom
3 = Livingroom
4 = Study
5 = Outdoor
6 = Kitchen
7 = Basement
1
9.2
Description of the installer level parameters
Tab.26 Factory settings
Parameter
Text display
Adjustment range
160
AP001
Blocking input setting (1: Full blocking, 2: Partial
blocking, 3: User reset locking)
1 = Full blocking
2 = Partial blocking
3 = User reset locking
4 = Backup Relieved
5 = Heat Pump Relieved
6 = Heat Pump And backup Relieved
7 = High Tariff Low Tariff
8 = Photovoltaic Heat Pump Only
9 = Photovoltaic Heat Pump And backup
10 = Smart Grid ready
11 = Heating Cooling
1
9 Settings
7625116 - v.04 - 17012017
45