5.3.2
Location of the boiler
Use the guidelines and the required installation space as a basis for de
termining the correct place to install the boiler.
When determining the correct installation space, take account of the
permitted position of the flue gas discharge and/or air supply outlet.
Ensure that there is sufficient space around the boiler for good access
and ease of maintenance.
Danger
It is forbidden to store, even temporarily, combustible products
and substances in the boiler or near the boiler.
Caution
Mount the boiler on a strong and solid wall (at least half-brick
brickwork with calcium silicate bricks). Build a reinforcing struc
ture if necessary.
The boiler must be installed in a frost-free area.
The boiler must have an earthed electrical connection.
A connection to the drain must be present for the condensate
drain close to the boiler.
The specified minimum space is required for standard mainte
nance work. For installation and extensive servicing work, there
must be at least 1 m x 1 m of clear space in front of the boiler.
Caution
If the power cord is permanently connected, you must always in
stall a main bipolar switch with an opening gap of at least 3 mm
(BS EN 60335-1).
5.4
Transport
The boiler is delivered on a pallet. The delivery includes 2 packages. One
package with the boiler and one package with individual parts and techni
cal documentation. See diagram for dimensions. The base of the package
is a pallet 80 cm wide. This means that it can be transported with a pallet
truck or using four-wheel transport boards. Without the packaging, the
boiler is 60 cm wide, meaning it will fit through all standard doorways.
Important
Always transport the boiler as close to the mounting plate as pos
sible before the packaging is removed.