P-1609 Condensate Pipe Replacement

IBC Technologies Inc.

1-844-432-8422

|

www.ibcboiler.com

120-521E0

August 02, 2023

Released Document

1 of 4

Installation Instructions- CX

Warning

This replacement kit shall be installed by a qualified service agent in accordance with these
instructions and all applicable codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly a fire, an explosion or production of
carbon monoxide may result causing property damage, personal injury or loss of life.

The qualified service agency is responsible for the proper installation of this kit. The installation
is not proper and complete until the operation is checked as specified in these instructions.

Danger

Never operate the combi boiler unless the trap is filled with water. Failure to comply will result in
severe personal injury or death.

Condensate Pipe - CX

Part #

Description

Quantity

251-223

Condensate Trap Bracket

1

255-159

Condensate Trap Bracket Seal

1

150-029

Screw, SHC, Zn, ¼-20 x ¾

2

190-309

EPDM Tubing, 1.5 x 1.25

1

190-310

PP-R Pipe 32 x 4.4

1

150-438

Hose Clamp, S/S, ¾ - 1¾

2

When to Install the P-1609 Condensate Pipe Replacement Kit

Install the P-1609 kit if you need to replace a leaking or damaged condensate pipe on a CX unit.