Replacement of Condensate Pipe

Preparing the Unit for Servicing

1. Remove call(s) for heat.

2. Remove power to the unit at a wall switch or a breaker.

3. Shut off gas supply to the boiler.

4. Allow the boiler to cool down.

Do not drain the boiler unless freezing conditions are expected during this procedure.

5. Remove the front cover, and then remove the four Torx 20 screws on the top panel of the combi boiler.

Removing and Replacing the CX Condensate Pipe Assembly

1. Pull back the clip to release the condensate

trap, and pull the trap downwards to
remove, and retain the trap.

2. Remove the two screws (A) securing the condensate trap bracket (B) to the base panel.

3. Release tension on both hose clamps.

One hose clamp (C) secures the
EPDM tube to the heat exchanger
condensate pan drain and one hose
clamp (D) secures the EPDM tube to
the PP-R pipe.

4. Pull the PP-R pipe (E) out from the condensate trap opening.