Grandview
®
G800EH Gas Fireplace |
91
maintenance
IFC (Integrated Fireplace Control) Error Codes
The IFC (Integrated Fireplace Control) in this appliance has an LED which can inform of any error codes as a result of
the appliance not turning on. The error codes are noted below.
NOTE: Depending on the appliance this may or may not be visible.
- Error codes:
All error codes are displayed on a set of
three LEDs located beside the SW1 switch.
- Low battery
: When backup battery is under 4V the
RED LED light (located beside the SW1 switch) will pulse
steadily. A double beep will be made by the IFC whenever
a command is made when backup batteries are below 4V.
Replace with 4 x AA alkaline batteries.
- Flame sense problem
: If the pilot flame is not detected
or the flame sense system is not satisfied the RED LED light
will pulse with 2 flashes until corrected.
Possible causes of flame sense problems
- The pilot is not engulfing the flame sense
- Pilot light shrinks in size
- The flame sense wire is not connected to the IFC
module.
- Proper grounding
- Flame sense and pilot hood are clean and free of any
debris
- The flame sense has no continuity (Ohms)
- The pilot flame is fluttering and not engulfing and
moving away from the flame sense
- Lockout
: If three trials for ignition fail the RED LED
indicator will pulse three times in intervals. To clear lockout,
turn the remote control hand-held to OFF position and then
back to ON position.
Error code LED
SW1
IFC (Integrated Fireplace Control) Error Codes
Summary of Contents for Grandview G800EH
Page 95: ...Grandview G800EH Gas Fireplace 95 notes ...
Page 100: ...100 Grandview G800EH Gas Fireplace warranty ...
Page 101: ...Grandview G800EH Gas Fireplace 101 notes ...
Page 102: ...102 Grandview G800EH Gas Fireplace notes ...
Page 103: ......