Grandview
®
G800EH Gas Fireplace |
51
installation
(Propane & Natural Gas)
The Diagram shows minimum vent runs with 4" x 6-5/8" venting using the Regency direct vent system or rigid vent system.
A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum
continuous
vent maximum horizontal length
of 2ft (0.6 m).
Note: Must use optional rigid pipe adaptor (Part # 510-994) when using Rigid Pipe vent systems.
Maintain clearance to combustibles.
For all other venting arrangements, see Venting Arrangements - Horizontal Termination - Rigid Pipe and Direct Vent System (Flex) in this
manual.
2
0
12
6
4
8
10
2
0
6
4
8
Vertical Height (Feet)
Rigid 44-"(1.1m)
Horizontal (Feet)
Max. 24”(0.6m)
Flex 44"(1.1m)
Top Vented
Set #1 (2" open) up to 1' horizontal
Factory Setting - no restrictor required greater than 1'
horizontal
Venting Arrangements for Horizontal Terminations - Flex Vent/Rigid Pipe
4" x 6-5/8" (102 mm x 168 mm)