28
| Grandview
®
G800EH Gas Fireplace
installation
Cool Wall Installation - Framing
Framing Dimensions Description
Cool Wall
Cool Wall
with Finishing Trim or Faceplate
M
Framing Width
36-1/2" (927mm)
37-1/2" (952mm)
N*
Framing Height
43" (940mm)
O
Framing Depth
22" (559mm)
P
Corner Facing Wall Width
42-1/2" (1035mm)
Q
Corner Facing Wall Width
60" (1524mm)
R
Framed Chase Ceiling Enclosure
82" (2083mm)
S
Vent Centerline Height
44" (1118mm)
T
Gas Connection Height
1-1/2" (38mm)
U
Gas Connection Inset
6-3/8" (162mm)
V
Gas Connection Width
3" (76mm)
W
Clearance to Corner of Unit
2-3/4" (70mm)
* Important: Framing height requires consideration of the hearth height. Dimension N = N + the thickness of the installed hearth.
Q
P
R
M
N
O
S
S
U
T
V
Combustible header
Top Vent
Rear Vent
W
Corner=Top Vent Only
IMPORTANT: Corner applications are vented from the top
only - rear venting cannot be used.
Note: The 2 standoffs at the rear of the appliance may be removed as these are not required in this application. Ensure that any screws that are
removed are reinstalled. The 2 standoffs can be recycled/discarded.
**The framing depth/width does not take into account dry wall/wood or similar materials against the back /side wall. The framing
depth will need to change based on the thickness of the material
(example: M - 36-1/2" framing width + 1/2" drywall = 37")
(example: M Outside finish with finishing trim/faceplate - 37-1/2" framing width + 1/2" drywall = 38")
(example: O - 16-7/8" framing depth + 1/2" drywall = 17-3/8")
**
**