Grandview
®
G800EH Gas Fireplace |
33
installation
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may
NOT
be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are
not adhered to. It is of greatest importance that this fireplace
and vent system be installed only in accordance with these
instructions.
Clean Front Installation (Non Cool Wall) - Clearances
The clearances listed below are minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this fireplace and vent system be installed only in accordance with these instructions.
Minimum Vent Clearances
to Combustibles
G800EH Clearance Requirements
Clearance:
Dimension
Measured From:
A: Mantel Height
(min.)
20" (508mm)
Top of Fireplace Opening
B: Sidewall
25" (635mm)
Side of Fireplace Opening
C: Ceiling
36-1/2" (927mm)
Top of Fireplace Opening
D: Mantel Depth
(max.)
12" (305mm)
Front of Fireplace Opening
E: Alcove Width
84" (2134mm)
Wall to Wall (Minimum)
F: Alcove Depth
36" (914mm)
Front to Back Wall (Maximum)
Notes:
0"
No Hearth Required
Horizontal Top
2" (51mm)
Horizontal Side
1-1/2 " (38mm)
Horizontal Bottom
1-1/2" (38mm)
Vertical Vent
1-1/2" (38mm)
Alcove
E
F
C
D
A
E
F
The
HeatWave
Duct Kit has different
clearance and framing requirements, check
the
HeatWave
manual for details.
See mantle chart on next page.