SAFETY NOTICE:

If this heater is not properly installed, a house 

fire may result.  For your safety, follow the in-

stallation instructions. Never use make-shift 

compromises during the installation of this 

heater. Contact local building or fire officials 

about permits, restrictions and installation 

requirements in your area.

CAUTION!

Please read this entire manual before you 

install or use your new room heater. 

Failure 

to follow instructions may result in property 

damage, bodily injury, or even death.

Improper Installation Could Void

Your Warranty!

CERTIFIED FOR USA and CANADA

SAFETY TESTED TO UL 1482-2010 and ULC-S627-2000

US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVE

WASHINGTON STATE APPROVED

United States Stove Company

227 Industrial Park Road

P.O. Box 151

South Pittsburg, TN 37380

SAVE THESE INSTRUCTIONS

THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU 

TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

851879

MODEL: 3000 (L), (LN)

CM

C

US

Summary of Contents for 3000 (L)

Page 1: ...ll or use your new room heater Failure tofollowinstructionsmayresultinproperty damage bodily injury or even death Improper Installation Could Void Your Warranty CERTIFIED FOR USA and CANADA SAFETY TES...

Page 2: ...E FIRE DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED DO NOT BURN GARBAGE FLAMMABLE FLUID SUCH AS GASOLINE NAPHTHA OR MOTOR OIL DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTE...

Page 3: ..._____ Reason for Purchase qAlternative Heat qMain Heat Source qDecoration qCost qOther_________________________ What was the determining factor for purchasing your new appliance _______ I have read th...

Page 4: ...4 Ussc CUT HERE CUT HERE Fold Here Fold Here United States Stove Company P O Box 151 South Pittsburg TN 37380 Fold Here Place Stamp Here...

Page 5: ...nector components required for your particular chimney installation Assembly Flue Collar Assembly 1 Mount the flue collar to the top of the unit as shown using the 3 5 16 18 x 1 1 2 bolts 3 washers an...

Page 6: ...essary depending on the trim kit you have After trim assembly attach to the pedestal base at the location shown using the screws provided Ash Pan Assembly If not already installed slide the ash pan in...

Page 7: ...BUTION DUCT OR SYSTEM A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to...

Page 8: ...fication to R value k factor is given with a required thickness T in inches R 1 k x T C factor is given R 1 C Example If the floor protector is 4 brick with a C factor of 1 25 over 1 8 mineral board w...

Page 9: ...r vertical walls and for vertical flue pipe The chimney connector must not pass through an attic or roof space closet or similar concealed space a floor or a ceiling For Canadian installations where p...

Page 10: ...nd of the section toward the chimney Any installation with a horizontal run of chimney pipe must conform to NFPA 211 You may contact NFPA National Fire Protection Association and request the latest ed...

Page 11: ...the draft effect your stove s performance is directly dependent on an adequate draft from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connec...

Page 12: ...same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance t...

Page 13: ...s sociation NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed...

Page 14: ...chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm sep aration area contain...

Page 15: ...smoke rollout occurs wood burns poorly or back drafts occur whether or not there is combustion present 2 Existing fuel fired equipment in the house such as fireplaces or other heating appliances smel...

Page 16: ...conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wood used was too d...

Page 17: ...ady to ignite the stove by lighting the paper and kindling wood inside the combustion chamber When you have achieved a good bed of hot embers we recommend the following burn procedures HEATING Control...

Page 18: ...nse in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney connector...

Page 19: ...product that may scratch the glass Use a specialized product available in the stores where wood stoves are sold The glass should be washed only when the heater is cold Do not abuse the glass door by s...

Page 20: ...20 Ussc REPAIR PARTS 1 8 9 11 40 17 18 20 19 16 15 23 25 26 24 39 35 36 37 38 27 29 30 28 33 34 31 12 13 14 32 5 6 7 2 3 4 22 21 10 4 3 1 5 6 7 2 9 8 10 11 Feed Door Assembly...

Page 21: ...528 Air Deflector 1 17 40292A Flue Collar 1 18 88032 Flue Collar Gasket 1 7 Ft 19 83432 5 16 18 x 1 1 2 Hex Head Bolt 3 20 83045 Washer 5 16 ID x 3 4 OD 3 21 83431 Weld Tab 3 22 89066 Firebrick 4 5 x...

Page 22: ...odel number which is on the nameplate attached to the heater when ordering repair parts always give the following infor mation as shown in this list 1 The part number 2 the part description 3 the mode...

Page 23: ...23 Ussc NOTES...

Page 24: ...Ussc 24 NOTES...

Page 25: ...et qui se trouve sur la plaque signal tique fix e sur l appareil de chauffage lors de commandes de pi ces d tach es donnez toujours les informations suivantes telles qu illustr es dans cette liste 1 L...

Page 26: ...t ou en la claquant N utilisez pas le po le si la vitre est cass e Si la vitre de votre po le se brise remplacez la uniquement par une vitre fournie par votre vendeur d appareils de chauffage Ne subst...

Page 27: ...ement Il en r sulte que des r sidus de cr osote s accumulent dans l int rieur de la conduite Une fois allum e cette cr osote cr e un feu extr mement chaud Lorsque vous br lez du bois le raccord de che...

Page 28: ...bon lit de braises chaudes nous recommandons les proc dures de chauffage suivantes CHAUFFAGE Une combustion ma tris e est la technique la plus efficace de chauffage au bois car elle vous permet de s...

Page 29: ...s extr mes il peut pourrir au lieu de s cher Ce point ne peut pas tre exag r la grande majorit des probl mes li s au fonctionnement d un po le bois est due au fait que le bois utilis soit trop tendre...

Page 30: ...de fa on continue une dispersion des fum es a lieu le bois br le mal ou des contre explosions se produisent qu il y ait ou non des mati res combustibles 2 Les appareils foyer existants au sein du domi...

Page 31: ...n e M thode D D gagement de 2 50 8 mm avec un membre de paroi combustible Commencez avec une partie de chemin e Solid Pak fabriqu e en usine agr e d au moins 12 304 mm de diam tre int rieur avec une i...

Page 32: ...et de blocage Faites nettoyer la chemin e avant d installer et de faire fonctionner le po le Lors du raccordement du po le travers une paroi combustible vers une chemin e en ma onnerie des m thodes s...

Page 33: ...chemin e etc Maintenez un d gagement appropri avec la structure tel que recommand par le fabriquant La chemin e doit avoir la hauteur requise au dessus du toit ou d autres obstructions pour des raiso...

Page 34: ...l effet de tirage les performances de votre po le d pendent directement du bon tirage de votre chemin e Les recommandations suivantes peuvent tre utiles pour l installation de votre chemin e 1 Ne con...

Page 35: ...tale de tuyau de chemin e doit tre conforme NFPA 211 Vous pouvez contacter la NFPA Association nationale de protection contre les incendies et demander la derni re dition du standard 211 de la NFPA Po...

Page 36: ...pour un tuyau de carneau vertical Le raccord de chemin e ne doit pas passer travers un grenier ou un espace du toit des toilettes ou des espaces confin s similaires un plancher ou un plafond Dans une...

Page 37: ...horizontale du raccord de chemin e le protecteur de sol devra passer sous celui ci et d passer de deux pouces de chaque c t Caract ristique de la conversion la valeur R le facteur k est donn avec une...

Page 38: ...ONDUIT OU CIRCUIT DE DISTRIBUTION D AIR UNE SOURCE D AIR FRAIS DANS LA PI CE OU L ESPACE CHAUFF DEVRA TRE FOURNIE SI N CESSAIRE POSITIONNER LE PO LE Il est tr s important de positionner le po le bois...

Page 39: ...es Apr s l assemblage de l habillage fixez le la base du socle l endroit indiqu en utilisant les vis fournies Assembl e de Casserole de Cendre Enlevez la casserole de cendre du foyer Sous le foyer il...

Page 40: ...emin e et du raccord de chemin e n cessaires pour votre installation particuli re de chemin e Pour les maisons mobiles voir page 13 Assemblage Assemblage de la buse 1 Montez la buse sur le haut de l u...

Page 41: ...4 Ussc D COUPEZ ICI D COUPEZ ICI Pliez ici Pliez ici United States Stove Company P O Box 151 South Pittsburg TN 37380 Pliez ici Placez votre timbre cet endroit...

Page 42: ...ource de chauffage qD coration qCo t qAutre _________________________ Quel fut le facteur d terminant lors de l achat de votre nouvel appareil _______ J ai lu le guide d utilisation qui accompagne cet...

Page 43: ...LAISSEZ PAS LE PO LE SANS SURVEILLANCE LORSQUE LA PORTE EST L G REMENT OUVERTE NE BR LEZ PAS DE D CHETS NI DE FLUIDES INFLAMMABLES TELS QUE L ESSENCE LE NAPTHA OU L HUILE POUR MOTEUR NE CONNECTEZ PAS...

Page 44: ...gences d installation de votre r gion ATTENTION Lisez attentivement toutes les instructions avant de commencer l installation ou de faire fonctionner ce po le Une installation incorrecte peut annuler...

Reviews: