background image

Ussc 

17

LE

S P

RE

MIE

RS 

FE

UX

La 

pei

ntu

re 

fra

îch

e d

e v

otre

 po

êle

 a 

bes

oin

 d'

être

 cu

ite

 po

ur p

rés

erv

er s

a q

ual

ité

. U

ne 

foi

s q

ue 

le 

com

bus

tib

le 

est

 co

rre

cte

men

allu

mé,

 fa

ite

s u

niq

uem

ent

 b

rûl

er 

de 

pet

its

 fe

ux 

dan

s v

otre

 p

oêl

e lo

rs 

des

 q

uat

re 

pre

miè

res

 h

eur

es 

de 

fon

ctio

nne

men

t. 

N'o

uvr

ez 

jam

ais

 la

 co

mm

and

e d

'ai

r p

lus

 qu

e n

éce

ssa

ire

 afi

n d

'ob

ten

ir u

ne 

vite

sse

 de

 co

mbu

stio

n m

oye

nne

.

Ass

ure

z-v

ous

 qu

e la

 ci

rcu

lat

ion

 d'

air 

soi

t s

uffi

san

te 

lor

s d

u tr

aite

men

t d

u p

oêl

e. L

es 

ode

urs

 po

urr

ont

 s'

éch

app

er l

ors

 de

3 o

u 4

 pr

em

ier

s fe

ux.

 N

e d

ém

arr

ez 

jam

ais

 vo

tre

 po

êle

 à 

l'e

xté

rie

ur. 

Vou

s n

e s

ere

z p

as 

en 

mes

ure

 de

 co

nst

ate

r s

i v

ous 

sur

cha

uffe

z.

ALL

UM

AG

E

Apr

ès 

vou

s ê

tre

 as

sur

é q

ue 

les

 co

mm

and

es 

d'a

dm

iss

ion

 d'

air 

du 

poê

le 

éta

ien

t c

om

plè

tem

ent

 ou

ver

tes

 (ti

rée

s c

om

plè

tem

ent 

ver

s v

ous

), p

lac

ez 

plu

sie

urs

 fe

uille

s d

e p

api

er f

roi

ssé

es 

au 

cen

tre

 de

 la

 ch

am

bre

 de

 co

mbu

stio

n. P

lac

ez 

8 à

 10

 pe

tits

 m

orc

eau

de 

boi

s d

'al

lum

age

 se

cs 

au-

des

sus

 du

 pa

pie

r e

n fo

rm

e d

e te

nte

. V

ous

 po

uve

z é

gal

em

ent

 pl

ace

r q

uel

que

s m

orc

eau

x d

boi

s d

e c

hau

ffa

ge,

 m

ais

 sé

lec

tio

nne

z le

s p

lus

 pe

tits

. A

ucu

n p

rod

uit 

chi

miq

ue 

ne 

doi

t ê

tre

 ut

ilis

é p

our

 al

lum

er l

e fe

u.

Ava

nt d

'al

lum

er l

e p

api

er e

t le

 bo

is 

d'a

llu

mag

e, i

l v

ous

 es

t re

com

man

dé 

de 

cha

uffe

r la

 ch

em

iné

e. C

ela

 es

t ré

alis

é a

fin 

d'é

vite

les

 pr

obl

èm

es 

de 

con

tre

-ex

plo

sio

n s

ouv

ent

 du

s à

 un

e p

res

sio

n n

éga

tiv

e d

ans

 la

 m

ais

on.

 Si

 te

l e

st l

e c

as,

 ou

vre

z lé

gèr

em

ent 

une

 fe

nêt

re 

prè

s d

u p

oêl

e e

t to

rde

z e

nse

mbl

e q

uel

que

s fe

uill

es 

de 

pap

ier

 jo

urn

al e

n fo

rm

e d

e to

rch

e. A

llu

mez

 ce

tte

 to

rch

en 

pap

ier

 et

 m

ain

ten

ez-

la 

aus

si p

rès

 qu

e p

oss

ibl

e d

e la

 bo

uch

e d

u tu

yau

 à 

l'in

tér

ieu

r d

e la

 ch

am

bre

 de

 co

mbu

stio

n p

our 

cha

uffe

r la

 ch

em

iné

e. U

ne 

foi

s q

ue 

le 

cou

ran

t a

sce

nda

nt e

st i

niti

é, v

ous

 êt

es 

prê

t p

our

 al

lum

er 

le 

poê

le 

en 

allu

man

t le 

pap

ier

 et

 le

 bo

is 

d'a

llu

mag

e à

 l'in

tér

ieu

r d

e la

 ch

am

bre

 de

 co

mbu

stio

n.

Lor

squ

e v

ous

 av

ez 

obt

enu

 un

 bo

n li

t d

e b

rai

ses

 ch

aud

es,

 no

us 

rec

om

man

don

s le

s p

roc

édu

res

 de

 ch

auf

fag

e s

uiv

ant

es 

:

CH

AU

FF

AG

E

Une

 co

mbu

stio

n m

aîtr

isé

e e

st l

a te

chn

iqu

e la

 pl

us 

effi

cac

e d

e c

hau

ffa

ge 

au 

boi

s c

ar e

lle

 vo

us 

per

met

 de

 sé

lec

tio

nne

r le

 ty

pe 

de 

com

bus

tio

n q

ue 

vou

s s

ouh

aite

z p

our

 ch

aqu

e s

itu

atio

n d

onn

ée.

 Le

 bo

is 

brû

ler

a le

nte

men

t s

i la

 co

mm

and

e d

'ad

mis

sio

d'a

ir d

u p

oêl

e à

 bo

is 

est

 ré

glé

e p

our

 ré

dui

re 

l'a

ppr

ovi

sio

nne

men

t e

n o

xyg

ène

 da

ns 

la 

cha

mbr

e d

e c

om

bus

tio

n a

u m

ini

mum

D'a

utre

 pa

rt, 

le 

boi

s b

rûl

era

 ra

pid

em

ent

 si 

la 

com

man

de 

d'a

ir e

st r

égl

ée 

pou

r la

iss

er u

ne 

plu

s g

ran

de 

qua

ntit

é d

'ox

ygè

ne 

dan

la 

cha

mbr

e d

e c

om

bus

tio

n. L

a c

om

man

de 

d'a

dm

iss

ion

 d'

air 

de 

vot

re 

poê

le 

est

 trè

s s

im

ple

. S

i v

ous

 la

 tir

ez 

com

plè

tem

ent 

ver

s v

ous

, e

lle

 es

t c

om

plè

tem

ent

 ou

ver

te.

 S

i v

ous

 la

 po

uss

ez 

jus

qu'

à c

e q

u'e

lle

 s'

arr

ête

, l'

air 

de 

com

bus

tio

n e

st r

édu

it a

min

im

um

.  

Les

 co

ndi

tio

ns 

de 

fon

ctio

nne

men

t r

éel

les

 p

euv

ent

 d

onn

er 

des

 ré

sul

tat

s tr

ès 

diff

ére

nts

 d

e c

eux

 o

bte

nus

 lo

rs 

des

 te

sts

 se

lon

 le

s e

spè

ces

 de

 bo

is 

util

isé

es,

 le

ur h

um

idi

té,

 la

 ta

ille

 et

 la

 de

nsi

té 

des

 pi

èce

s, l

a lo

ngu

eur

 de

 la

 ch

em

iné

e, 

l'a

ltit

ude

 et

 la

 te

mpé

rat

ure

 ex

tér

ieu

re.

ATT

EN

TIO

N : 

Ne 

mod

ifie

z ja

mai

s le

 re

gist

re 

à c

oul

iss

e o

u la

 pl

age

 de

 ré

gla

ge 

afin

 d'

aug

men

ter

 la

 co

mbu

stio

n p

our 

que

lqu

e ra

iso

n q

ue 

ce 

soi

t. L

e fa

ire

 pe

ut e

ntra

îne

r d

es 

dom

mag

es 

de 

l'a

ppa

rei

l d

e c

hau

ffa

ge 

et a

nnu

ler

a v

otre

 ga

ran

tie

.

3000

Rég

lag

es 

prin

cip

aux

 d’

air

(Le

 re

gis

tre

 à 

cou

lis

se 

est

 si

tué

 au

 ce

ntre

 du

 po

êle

 so

us 

le 

pla

tea

u d

u fo

yer

)

(R

égl

age

 du

 re

gis

tre

 : T

ire

r s

ur l

e re

gis

tre

 au

gm

ent

e l’

air)

Rég

lag

e d

e la

 vi

tes

se 

de 

la 

sou

ffla

nte 

éle

ctr

iqu

(Va

ria

ble

)

(La

 so

uffl

ant

e e

st e

n p

osi

tio

n é

lev

ée 

lor

squ

’el

le 

est 

allu

mée

 (O

N), 

 To

urn

ez 

dan

s le

 se

ns 

des

 ai

gui

lle

s d

’un

mon

tre

 ju

squ

’à 

ce 

qu’

elle

 s’

arrê

te 

sur

 «L

OW

» (F

aib

le)

.)

Vitesse de 

combustion

Réglez le registre à partir de la 

position complètement fermée

Temps de 

combustion

Vitesse de la 

soufflante

Faible

1/8” (3.2mm)

@ 30 minutes

Faible

Moyenne - Faible

1/4” (6.3mm)

@ 30 minutes

Faible

Moyenne - Élevée

1-1/8” (12.7mm)

@ 30 minutes

Faible

Élevée

approx. 3” (76mm)

Toutes les minutes

Élevée

Summary of Contents for 3000 (L)

Page 1: ...ll or use your new room heater Failure tofollowinstructionsmayresultinproperty damage bodily injury or even death Improper Installation Could Void Your Warranty CERTIFIED FOR USA and CANADA SAFETY TES...

Page 2: ...E FIRE DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED DO NOT BURN GARBAGE FLAMMABLE FLUID SUCH AS GASOLINE NAPHTHA OR MOTOR OIL DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTE...

Page 3: ..._____ Reason for Purchase qAlternative Heat qMain Heat Source qDecoration qCost qOther_________________________ What was the determining factor for purchasing your new appliance _______ I have read th...

Page 4: ...4 Ussc CUT HERE CUT HERE Fold Here Fold Here United States Stove Company P O Box 151 South Pittsburg TN 37380 Fold Here Place Stamp Here...

Page 5: ...nector components required for your particular chimney installation Assembly Flue Collar Assembly 1 Mount the flue collar to the top of the unit as shown using the 3 5 16 18 x 1 1 2 bolts 3 washers an...

Page 6: ...essary depending on the trim kit you have After trim assembly attach to the pedestal base at the location shown using the screws provided Ash Pan Assembly If not already installed slide the ash pan in...

Page 7: ...BUTION DUCT OR SYSTEM A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to...

Page 8: ...fication to R value k factor is given with a required thickness T in inches R 1 k x T C factor is given R 1 C Example If the floor protector is 4 brick with a C factor of 1 25 over 1 8 mineral board w...

Page 9: ...r vertical walls and for vertical flue pipe The chimney connector must not pass through an attic or roof space closet or similar concealed space a floor or a ceiling For Canadian installations where p...

Page 10: ...nd of the section toward the chimney Any installation with a horizontal run of chimney pipe must conform to NFPA 211 You may contact NFPA National Fire Protection Association and request the latest ed...

Page 11: ...the draft effect your stove s performance is directly dependent on an adequate draft from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connec...

Page 12: ...same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance t...

Page 13: ...s sociation NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed...

Page 14: ...chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm sep aration area contain...

Page 15: ...smoke rollout occurs wood burns poorly or back drafts occur whether or not there is combustion present 2 Existing fuel fired equipment in the house such as fireplaces or other heating appliances smel...

Page 16: ...conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wood used was too d...

Page 17: ...ady to ignite the stove by lighting the paper and kindling wood inside the combustion chamber When you have achieved a good bed of hot embers we recommend the following burn procedures HEATING Control...

Page 18: ...nse in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney connector...

Page 19: ...product that may scratch the glass Use a specialized product available in the stores where wood stoves are sold The glass should be washed only when the heater is cold Do not abuse the glass door by s...

Page 20: ...20 Ussc REPAIR PARTS 1 8 9 11 40 17 18 20 19 16 15 23 25 26 24 39 35 36 37 38 27 29 30 28 33 34 31 12 13 14 32 5 6 7 2 3 4 22 21 10 4 3 1 5 6 7 2 9 8 10 11 Feed Door Assembly...

Page 21: ...528 Air Deflector 1 17 40292A Flue Collar 1 18 88032 Flue Collar Gasket 1 7 Ft 19 83432 5 16 18 x 1 1 2 Hex Head Bolt 3 20 83045 Washer 5 16 ID x 3 4 OD 3 21 83431 Weld Tab 3 22 89066 Firebrick 4 5 x...

Page 22: ...odel number which is on the nameplate attached to the heater when ordering repair parts always give the following infor mation as shown in this list 1 The part number 2 the part description 3 the mode...

Page 23: ...23 Ussc NOTES...

Page 24: ...Ussc 24 NOTES...

Page 25: ...et qui se trouve sur la plaque signal tique fix e sur l appareil de chauffage lors de commandes de pi ces d tach es donnez toujours les informations suivantes telles qu illustr es dans cette liste 1 L...

Page 26: ...t ou en la claquant N utilisez pas le po le si la vitre est cass e Si la vitre de votre po le se brise remplacez la uniquement par une vitre fournie par votre vendeur d appareils de chauffage Ne subst...

Page 27: ...ement Il en r sulte que des r sidus de cr osote s accumulent dans l int rieur de la conduite Une fois allum e cette cr osote cr e un feu extr mement chaud Lorsque vous br lez du bois le raccord de che...

Page 28: ...bon lit de braises chaudes nous recommandons les proc dures de chauffage suivantes CHAUFFAGE Une combustion ma tris e est la technique la plus efficace de chauffage au bois car elle vous permet de s...

Page 29: ...s extr mes il peut pourrir au lieu de s cher Ce point ne peut pas tre exag r la grande majorit des probl mes li s au fonctionnement d un po le bois est due au fait que le bois utilis soit trop tendre...

Page 30: ...de fa on continue une dispersion des fum es a lieu le bois br le mal ou des contre explosions se produisent qu il y ait ou non des mati res combustibles 2 Les appareils foyer existants au sein du domi...

Page 31: ...n e M thode D D gagement de 2 50 8 mm avec un membre de paroi combustible Commencez avec une partie de chemin e Solid Pak fabriqu e en usine agr e d au moins 12 304 mm de diam tre int rieur avec une i...

Page 32: ...et de blocage Faites nettoyer la chemin e avant d installer et de faire fonctionner le po le Lors du raccordement du po le travers une paroi combustible vers une chemin e en ma onnerie des m thodes s...

Page 33: ...chemin e etc Maintenez un d gagement appropri avec la structure tel que recommand par le fabriquant La chemin e doit avoir la hauteur requise au dessus du toit ou d autres obstructions pour des raiso...

Page 34: ...l effet de tirage les performances de votre po le d pendent directement du bon tirage de votre chemin e Les recommandations suivantes peuvent tre utiles pour l installation de votre chemin e 1 Ne con...

Page 35: ...tale de tuyau de chemin e doit tre conforme NFPA 211 Vous pouvez contacter la NFPA Association nationale de protection contre les incendies et demander la derni re dition du standard 211 de la NFPA Po...

Page 36: ...pour un tuyau de carneau vertical Le raccord de chemin e ne doit pas passer travers un grenier ou un espace du toit des toilettes ou des espaces confin s similaires un plancher ou un plafond Dans une...

Page 37: ...horizontale du raccord de chemin e le protecteur de sol devra passer sous celui ci et d passer de deux pouces de chaque c t Caract ristique de la conversion la valeur R le facteur k est donn avec une...

Page 38: ...ONDUIT OU CIRCUIT DE DISTRIBUTION D AIR UNE SOURCE D AIR FRAIS DANS LA PI CE OU L ESPACE CHAUFF DEVRA TRE FOURNIE SI N CESSAIRE POSITIONNER LE PO LE Il est tr s important de positionner le po le bois...

Page 39: ...es Apr s l assemblage de l habillage fixez le la base du socle l endroit indiqu en utilisant les vis fournies Assembl e de Casserole de Cendre Enlevez la casserole de cendre du foyer Sous le foyer il...

Page 40: ...emin e et du raccord de chemin e n cessaires pour votre installation particuli re de chemin e Pour les maisons mobiles voir page 13 Assemblage Assemblage de la buse 1 Montez la buse sur le haut de l u...

Page 41: ...4 Ussc D COUPEZ ICI D COUPEZ ICI Pliez ici Pliez ici United States Stove Company P O Box 151 South Pittsburg TN 37380 Pliez ici Placez votre timbre cet endroit...

Page 42: ...ource de chauffage qD coration qCo t qAutre _________________________ Quel fut le facteur d terminant lors de l achat de votre nouvel appareil _______ J ai lu le guide d utilisation qui accompagne cet...

Page 43: ...LAISSEZ PAS LE PO LE SANS SURVEILLANCE LORSQUE LA PORTE EST L G REMENT OUVERTE NE BR LEZ PAS DE D CHETS NI DE FLUIDES INFLAMMABLES TELS QUE L ESSENCE LE NAPTHA OU L HUILE POUR MOTEUR NE CONNECTEZ PAS...

Page 44: ...gences d installation de votre r gion ATTENTION Lisez attentivement toutes les instructions avant de commencer l installation ou de faire fonctionner ce po le Une installation incorrecte peut annuler...

Reviews: