8. OPERATING
INSTRUCTIONS
Before Start-Up
Burners
Keep heater area clear and free from combustibles,
flammable liquids and chemicals. Do not obstruct the flow
of combustion and ventilation air.
Water
Water must be flowing through the heater during operation.
Ensure that the system is filled with water and that the
pump is operating. The heater should always have a
minimum of 40 GPM (151 lpm) water flowing through it.
Start-Up Procedures
Your pool/spa heater has been designed for years of safe
and reliable pool/spa water heating. It is available with
electronic ignition only. This manual provides installation,
operation, maintenance, and service information for these
heaters.
MODE
SERVICE
DOWN
UP
CONNECT
LCD DISPLAY
TEMP ADJUST
CONNECT MENU
SERVICE MENU
MODE KEY
ON / OFF
SWITCH
Figure 72. Heater Control Toggle Switch
If your heater has been installed correctly, operating the
heater is an easy task. The upper front panel of the heater
contains the control center that allows you to turn the
heater On or Off and adjust the temperature settings for
the pool or spa. The temperature range is factory-set from
65°F (18°C) to 104°F (40°C). See
Figure 72
for location of
toggle switch to turn the heater On and Off.
See "
Controls"
section on page
27
for additional details
about the use of the controls in the Control Adjustments
subsection.
After Start-Up
Feel the inlet and outlet pipes. Outlet pipe should be only
slightly warmer than the inlet. It should not be hot.
A
WARNING:
Should overheating occur or the gas
supply fail to shut off, turn off the manual gas control to
the appliance.
A
AVERTISSEMENT:
En cas de surchauffe ou
si l’alimentation en gaz ne s’arrete pas, fermez
manueiiement ie robinet d’arret de l’admission de gaz.
Water Pressure Switch
A water pressure switch is provided in the heater to shut off
the burners in the event that water supply is interrupted. It
is very important to verify that the switch electrically opens
and shuts off the gas valve when water flow to the heater is
interrupted. Otherwise, rapid and severe damage will likely
occur to the heater.
The water pressure switch should be checked and adjusted
for proper operation by a qualified service person at the
time of installation and periodically checked thereafter.
Refer to
"Water Pressure Switch Adjustment" on page
38
.
F10671
Figure 73. Water Pressure Switch
A
WARNING:
Operation of the heater without water
circulation will cause rapid and severe damage to the
heater, which will not be covered under warranty.
Summary of Contents for AVIA 264A
Page 67: ...67 2 H 1 R 1 H 7 S 2 C 3 C 5 S...
Page 68: ...68 1 F 2 F 2 G 1 M 4 M 5 M 6 M 7 M 8 M 10 M 6 G 3 G 4 G...
Page 69: ...69 1 B 2 B 2 F 1 P 3 P 2 P...
Page 70: ...70 1 V 2 V 3 V 11C 11 M OPTIONAL...
Page 71: ...71 14 H 15 H 4 H 12 M 7 H 9 H 7 C 8 C 12 H 13 H 16 H 11 H 10 H 10 C 9 C 8 H 6 H 5 H 3 H...
Page 146: ...67 2 H 1 R 1 H 7 S 2 C 3 C 5 S...
Page 147: ...68 1 F 2 F 2 G 1 M 4 M 5 M 6 M 7 M 8 M 10 M 6 G 3 G 4 G...
Page 148: ...69 1 B 2 B 2 F 1 P 3 P 2 P...
Page 149: ...70 1 V 2 V 3 V 11C 11 M OPTIONAL...
Page 150: ...71 14 H 15 H 4 H 12 M 7 H 9 H 7 C 8 C 12 H 13 H 16 H 11 H 10 H 10 C 9 C 8 H 6 H 5 H 3 H...