Faults and possible causes
117
8
8
Faults and possible causes
n
WARNING
Risk of injury when rectifying faults inappropriately
Delayed or incorrect repairs by unqualified personnel may result in
severe personal injury as well as in damages to the machine and
the environment.
Any faults occurring must be repaired
immediately
.
Only carry out repairs yourself if you have the appropriate
qualifications.
Fault
Possible cause
Measure
The conveyor belt does
not convey any fertiliser
into the fertiliser
spreader hopper
The universal drive shaft is not
connected or switched on.
The machine control unit is not
switched on.
The AXENT container is empty.
The fertiliser spreader is full.
The level sensors in the AXIS-Power-
Pack are dirty or defective.
The pre-metering sliders do not open.
Check the connections.
Check or clean the
sensors.
The conveyor belt does
not convey enough
fertiliser.
The universal drive shaft speed is
too slow.
The pre-metering sliders do not open
completely.
The consistency of the spreading ma-
terial is not suitable for spreading with
the AXENT large area spreader.
The conveyor belt
exhibits slippage.
The tension of the conveyor belt is
not set correctly.
Re-tighten the conveyor
belt
Summary of Contents for AXENT Series
Page 8: ...Intended use 1 2...
Page 32: ...Safety 3 26...
Page 54: ...Technical data 4 48...
Page 56: ...Transport without tractor 5 50...
Page 122: ...Spreading operation 7 116...
Page 124: ...Faults and possible causes 8 118...
Page 162: ...General maintenance and servicing 9 156...
Page 168: ...Index D...
Page 170: ......