General maintenance and servicing
9
122
9.2.4
Electric and electronic equipment
Electrical fuses
The power supply of the machine is fuse-protected by the ISOBUS cable of
the tractor.
The ISOBUS cable is protected against overload with a
60-ampere
and
30-ampere
fuse. The fuses are behind the maintenance flap.
Checking the electrical cables
Visually inspect all electrical cables for wear. Pay particular attention to
external damage or breakages.
Checking the lighting system function
The machine is equipped with a front and rear lighting system at the factory.
Check the function of the tail lights, brake lights, turn signals and position
lights.
[1] 30 A fuse
[2] 60 A fuse
Figure 9.1:
Fuses at the ISOBUS cable
1
2