COMMUNICATIONS PROTOCOL
TCP/IP communications setup command set
CubiScan 325 Service Manual
79
Set gateway address
This command is used to set the network gateway address on the Cubiscan 325. It can be the
address of a network server or router and is expressed in “dot” notation. Consult your network
administrator to obtain the network gateway address.
6+n
1
Carriage return
Control
(CR)
0Dh
7+n
1
Line feed
Control
(LF)
0Ah
Negative acknowledge format
Pos
Len
Description
Type
Range
ASCII
1
1
Start of text
Control
(STX)
02h
2
1
Read command
Alpha
(~)
7Eh
3
1
Gateway address
command
Alpha
(G)
47h
4
1
Neg. acknowledge
Alpha
(N)
4Eh
5
1
End of text
Control
(ETX)
03h
6
1
Carriage return
Control
(CR)
0Dh
7
1
Line feed
Control
(LF)
0Ah
Pos
Len
Description
Type
Range
ASCII
Command format
1
1
Start of text
Control
(STX)
02h
2
1
Set command
Alpha
(@)
40h
3
1
Gateway address command Alpha
(G)
47h
4
7-15
or n
IP address
Alpha
(0.0.0.0) to
(255.255.255.255)
4+n
1
End of text
Control
(ETX)
03h
5+n
1
Carriage return
Control
(CR)
0Dh
6+n
1
Line feed
Control
(LF)
0Ah
Acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Set command
Alpha
(@)
40h
3
1
Gateway address command Alpha
(G)
47h
4
1
Acknowledge
Alpha
(A)
41h
5
1
End of text
Control
(ETX)
03h
6
1
Carriage return
Control
(CR)
0Dh
Pos
Len
Description
Type
Range
ASCII