COMMUNICATIONS PROTOCOL
Cubiscan 325 command set
CubiScan 325 Service Manual
74
Values
This command causes the Cubiscan 325 to report various internal parameters. This is useful for
troubleshooting.
Pos
Len
Description
Type
Range
ASCII
Command format
1
1
Start of text
Control
(STX)
02h
2
1
Values command
Alpha
(V)
56h
3
1
End of text
Control
(ETX)
03h
4
1
Carriage return
Control
(CR)
0Dh
5
1
Line feed
Control
(LF)
0Ah
Acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Values command
Alpha
(V)
56h
3
1
Acknowledge
Alpha
(A)
41h
4
4
Length DBW
Numeric
00.0-99.9
8
1
Comma
Alpha
(,)
2Ch
9
4
Width DBW
Numeric
00.0-99.9
13
1
Comma
Alpha
(,)
2Ch
14
4
Height DBW
Numeric
00.0-99.9
18
1
Comma
Alpha
(,)
2Ch
19
4
Length CPI
Numeric
0000-9999
23
1
Comma
Alpha
(,)
2Ch
24
4
Width CPI
Numeric
0000-9999
28
1
Comma
Alpha
(,)
2Ch
29
4
Height CPI
Numeric
0000-9999
33
1
Comma
Alpha
(,)
2Ch
34
4
Length blanking
Numeric
0.00-9.99
38
1
Comma
Alpha
(,)
2Ch
39
4
Width blanking
Numeric
0.00-9.99
43
1
Comma
Alpha
(,)
2Ch
44
4
Height blanking
Numeric
0.00-9.99
48
1
Comma
Alpha
(,)
2Ch
49
4
Length gain
Numeric
00.0-99.9
53
1
Comma
Alpha
(,)
2Ch
54
4
Width gain
Numeric
00.0-99.9
58
1
Comma
Alpha
(,)
2Ch