![Quantronix CUBISCAN 325 Service Manual Download Page 81](http://html1.mh-extra.com/html/quantronix/cubiscan-325/cubiscan-325_service-manual_3467087081.webp)
COMMUNICATIONS PROTOCOL
Cubiscan 325 command set
CubiScan 325 Service Manual
71
Smallest box mode
This command causes the Cubiscan 325 to calculate measurements based on the smallest box.
3
1
Acknowledge
Alpha
(4)
34h
4
4
Index
Numeric
(0000-9999)
8
1
End of text
Control
(ETX)
03h
9
1
Carriage return
Control
(CR)
0Dh
10
1
Line feed
Control
(LF)
0Ah
Negative acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Serial put command
Alpha
(p)
70h
3
1
Neg. acknowledge
Alpha
(N)
4Eh
4
1
End of text
Control
(ETX)
03h
5
1
Carriage return
Control
(CR)
0Dh
6
1
Line feed
Control
(LF)
0Ah
Pos
Len
Description
Type
Range
ASCII
Command format
1
1
Start of text
Control
(STX)
02h
2
1
Smallest box command
Alpha
(j)
6Ah
3
1
End of text
Control
(ETX)
03h
4
1
Carriage return
Control
(CR)
0Dh
5
1
Line feed
Control
(LF)
0Ah
Acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Smallest box command
Alpha
(j)
6Ah
3
1
Acknowledge
Alpha
(A)
41h
4
1
End of text
Control
(ETX)
03h
5
1
Carriage return
Control
(CR)
0Dh
6
1
Line feed
Control
(LF)
0Ah
Negative acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Smallest box command
Alpha
(j)
6Ah
3
1
Neg. acknowledge
Alpha
(N)
4Eh
4
1
End of text
Control
(ETX)
03h
Pos
Len
Description
Type
Range
ASCII