![Quantronix CUBISCAN 325 Service Manual Download Page 73](http://html1.mh-extra.com/html/quantronix/cubiscan-325/cubiscan-325_service-manual_3467087073.webp)
COMMUNICATIONS PROTOCOL
Cubiscan 325 command set
CubiScan 325 Service Manual
63
Location identification
This command is used to set the Cubiscan 325 location identification. The location identification
is a six-digit code which uniquely identifies the Cubiscan 325 within the user’s operation. This
location identification is included in each measurement packet. This data is stored in permanent
memory and need only be set once for each Cubiscan 325.
Model
This command causes the Cubiscan 325 to change its current model designation. The Cubiscan
325 = 08.
Pos
Len
Description
Type
Range
ASCII
Command format
1
1
Start of text
Control
(STX)
02h
2
1
Location ID command
Alpha
(L)
4Ch
3
6
Location ID
Alpha
000000-ZZZZZ
9
1
End of text
Control
(ETX)
03h
10
1
Carriage return
Control
(CR)
0Dh
11
1
Line feed
Control
(LF)
0Ah
Acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Location ID command
Alpha
(L)
4Ch
3
1
Acknowledge
Alpha
(A)
41h
4
1
End of text
Control
(ETX)
03h
5
1
Carriage return
Control
(CR)
0Dh
6
1
Line feed
Control
(LF)
0Ah
Negative acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Location ID command
Alpha
(L)
4Ch
3
1
Neg. acknowledge
Alpha
(N)
4Eh
4
1
End of text
Control
(ETX)
03h
5
1
Carriage return
Control
(CR)
0Dh
6
1
Line feed
Control
(LF)
0Ah
Pos
Len
Description
Type
Range
ASCII
Command format
1
1
Start of text
Control
(STX)
02h
2
1
Model command
Alpha
(!)
21h