DIAGNOSTICS
Scale errors
Cubiscan 325 Service Manual
1 3
–Go to
Menu > Diagnose > Scale
. Compare the
LDW
and
LWT
values. If they are the same or
very similar, recalibrate the scale. Move on to the next step if this does not resolve your problem.
–If the scale is still not functioning properly, proceed to step 1 below.
Complete the following steps if there are still dashes in the weight field.
1. Make sure that the glass platform is securely in place.
2. Make sure that there are no objects on or leaning against the glass platform.
3. Make sure that all the controller box cables are securely attached.
4. Make sure that all load cell summing box cables are securely attached.
5. Make sure the scale card is in the load cell summing box.
6. Check the gap between the scale overload bolts. There should be about a 2mm gap
between the bolts. If needed, adjust the bottom bolt with a wrench.
7. Make sure that there are no objects on the platform and zero the Cubiscan 325 by tapping
the
Zero
button that is found on the main screen. If an accurate weight is not displayed in the
weight field, continue on to the next step.
8. Calibrate the scale. For instructions on how to do this, see
“Scale Calibration” on page 13
.
9. If, after completing the above steps, there are still dashes in the weight field, please contact
Cubiscan Technical Assistance at 801.451.7000.
Different load cells report different weights
Complete the following steps if the load cells are reporting different weights in each corner.
1. Make sure the glass platform is sitting on all four load cells and is level; adjust the feet
located in each corner if needed.
2. Make sure that no ball bearings have been lost. There should be one in each load cell cup.
3. Calibrate the scale. For more information on calibrating the scale, see
.
4. Balance the load cells. For more information, see
“Balancing the Load Cells” on page 23
5. If, after completing the above steps, the load cells are still reporting different weights, please
contact Cubiscan Technical Assistance at 801.451.7000.