DIAGNOSTICS
Dimensional errors
Cubiscan 325 Service Manual
6
5. Does the object you are measuring exceed or not meet the measurement range? The
measurement range for the Cubiscan 325 is 0.10 in (0.2 cm) to 36.00 x 24.00 x 24.0 0 in (90.0 x
60.0 x 60.0 cm).
6. Is the item you are measuring placed roughly in the center of the glass platform? The edges
of the glass platform may interfere with the measuring process when objects are placed too
close to the edge.
7. Go to
Menu > Diagnose > Gate
. The threshold and sensitivity values are listed for the width
and height. The threshold values should be between 450 and 700. The sensitivity values
should be 100. If your values are incorrect, run an automatic threshold test. When this test is
run the Cubiscan 325 finds the top and bottom limits and automatically picks the best values.
Move the gate to the middle of the Cubiscan 325 and then tap
ALL
. Make sure the platform
is empty of all objects. This test will take several minutes. Do not touch the gate during this
test.
8. Go to
Menu > Diagnose > Gate (Page 2 of 3)
. From this screen, you can run a masking test
to mask LED’s that may be malfunctioning. You should only run this test if 3 or less of the
LED’s are not working. Do not run the masking test if a large amount of yellow is displayed on
the LED beam bars. If too many LED’s are masked, the Cubiscan 325 will not be able to
measure objects. To run the masking test, start with the gate in the home position (right side)
and slowly move it all the way to the left, and back into the home position. Tap
Mask
.
9. If, after completing the above steps, you are still receiving the item exceeds boundary error,
please contact Cubiscan Technical Assistance at 801.451.7000.
Invalid yellow shapes in measurement results
There are generally two types of invalid yellow shapes that can occur in measurement results;
yellow specks or lines, or a large amount of yellow in the measurement area. Examples of these
are shown below. Refer to the appropriate section below according to the type of yellow shape
that is being displayed in the measurement results.
Yellow specks or lines
Complete the following steps to eliminate yellow specks or lines that appear in measurement
results.
Figure 2
Invalid yellow shapes in measurement results