PART REPLACEMENT
Replacing a load cell
Cubiscan 325 Service Manual
4 5
Complete the following steps to replace a load cell.
1. Power the Cubiscan 325 off.
2. Using two people, remove the glass platform and set
it aside.
3. Remove the two center cover thumb screws that are
located on the right side of the system. See
.
4. Slide the center cover to the left so that you can
access the load cell summing box.
5. Use the 5/64'' Allen wrench to remove the eight
screws holding the load cell summing box lid in
place and remove the lid. Refer to
.
6. Locate the damaged load cell cable and disconnect
the load cell connection wires by loosening the
corresponding flathead screw with a small flathead
screwdriver. Refer to
. You only need to
disconnect the wires that correspond to the
damaged load cell cable.
7. Remove the nut holding the load cell cable in the
load cell summing box using the 7/16'' wrench. Refer
to
8. Remove the cable from the load cell summing box
and use the two 7/16'' wrenches to loosen the metal
attachments on the damaged load cell cable.
Remove the attachments indicated in
and
. You will need these attachments for the
new load cell cable.
9. Remove the load cell ball from the damaged load
cell and keep it in a safe location.
10. Locate the damaged load cell body and remove the
black, plastic cover near the load cell. See
.
This cover protects the bolts that hold the load cell
in place. Use the flathead screwdriver to pry the
cover up.
11. Unscrew the two bolts holding the load cell in place
using the 3/8'' socket with a quarter inch ratchet.
Refer to
.
Figure 65
Load cell summing box
Figure 66
Wires drawing
Figure 67
Load cell cable nut
Figure 68
Load cell cable attachments
Load cell cable nut
Attachments