Communications Protocol
CubiScan 110-T Command Set
CubiScan 110-T
68
EXPANDED COMMUNICATION PROTOCOL
Length
5
Length
6
Length
6
Measure
Expanded:
Causes the instrument to initiate and communicate a measurement. This is a
legal for trade mode.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg. Ack.
Packet
Start Byte
<STX>
Start Byte
<STX>
Start Byte
<STX>
Command
(M) or (C)
Command
(M)
Command
(M)
Ack
(A)
Nack
(N)
CubiScan OR
Host
(C) or (H)
CubiScan or
Host
(C) or (H)
Location ID
(000000) –
(ZZZZZZ)
Measure or
Zero
(M) or (Z)
Comma
(,)
Package Count
(0000)‐(9999)
Comma
(,)
Year
(2000)‐(9999)
Back Slash
(/)
Month
(01)‐(12)
Back Slash
(/)
Day
(01)‐(31)
Comma
(,)
Hour
(00)‐(23)
Colon
(:)
Minute
(00)‐(59)
Colon
(:)
Second
(00)‐(59)
Comma
(,)
Length
(L000.00) –
(L999.99)
Comma
(,)
Length Status
(00)‐(99)
Comma
(,)
Length Units
(in) or (cm) or
(mm)
Comma
(,)
Width
(W000.00) –
(W999.99)
Comma
(,)
Width Status
(00)‐(99)
Comma
(,)