Calibration
Calibrating the Scale
CubiScan 110-T
29
Calibrating the Scale
To perform the calibration, you will need the following:
•
Official test weight in the range of 50-100 pounds (25-50 kg) (it is
recommended that you calibrate with the maximum weight)
Calibrating without an accurate known weight can make all future weight
readings inaccurate. To calibrate the scale using the touchscreen, proceed
as follows.
N
OTE
When calibrating the scale, the CubiScan 110-T must be stable with no movement
of the platform such as that caused by vibration or air movement.
1. At the home screen, tap
CALIBRATE
.
2. The calibration menu is displayed at the bottom of the screen. Select the
Scale
option if it is not already selected. If the weight units displayed
Figure 21
Home Screen