Communications Protocol
CubiScan 110-T Command Set
CubiScan 110-T
64
Comma
(,)
Dim Unit
(E) or (M)
Comma
(,)
Weight
(K000.00) – (K999.99)
Comma
(,)
Dim Weight
(D000.00) – (D999.99)
Comma
(,)
Weight unit
(E) or (M)
Comma
(,)
Factor
(F0000) – (F9999)
Comma
(,)
International
OR Domestic
(D) or (I)
End Bytes
<ETX><CR><LF
>
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><
LF>
Length
5
Length
62
Length
8
Read Value:
Causes the instrument to transmit a specific parameter.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg. Ack.
Packet
Start Byte
<STX>
Start Byte
<STX>
Start Byte
<STX>
Command
(R)
Command
(R)
Command
(R)
Value
Number
(0000)‐(9999)
Ack
(A)
Nack
(N)
Value Number
(0000)‐(9999)
Comma
(,)
Value Data
See Value Table
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
Length
9
Length
11+
Length
6
Scale Data:
Causes the instrument to transmit scale only data.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg. Ack.
Packet
Start Byte
<STX>
Start Byte
<STX>
Start Byte
<STX>
Command
(s)
Command
(s)
Command
(s)
Ack
(A)
Nack
(N)
Weight
(K000.00) –
(K999.99)
Comma
(,)
Weight Units
(lb) or (kg)
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
Length
5
Length
16
Length
6