CubiScan 110-T
17
Chapter 3
Operation
This chapter provides instructions for operating the CubiScan 110-T.
N
OTE
The platform of the CubiScan should be kept clean and free of objects that are not
being measured.
Before You Begin
Follow the procedures below to turn on the CubiScan. The CubiScan should
be turned on before you start Qbit (if applicable).
1. Make sure there are no packages or objects on the CubiScan platform.
2. Turn on the CubiScan 110-T via the power strip. The CubiScan performs
self-calibration and diagnostic procedures that take about five seconds.
Do not touch the CubiScan platform during these five seconds.
N
OTE
Do not lean on or touch the CubiScan platform or the package while a package is
being cubed and weighed. Any kind of contact with the platform during the
measurement process can alter the weight or sensor reading.
N
OTE
You should occasionally verify that the zero settings on the CubiScan are correct.
To do this, take a measurement with nothing on the scale and see if all values
recorded are zero. The CubiScan’s empty weight and measurements can be reset
to zero (zeroed) at any time (refer to the Qbit User Guide or to
).
Disconnect all power to the CubiScan 110-T before servicing or making any
connections.
WARNING