Communications Protocol
CubiScan 110-T Command Set
CubiScan 110-T
63
Length
15+
Length
6
Length
6
Stream Begin:
This command is executed first. It initializes a streaming file transfer.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg. Ack.
Packet
Start Byte
<STX>
Start Byte
<STX>
Start Byte
<STX>
Command
(p)
Command
(p)
Command
(p)
Stream
(S)
Ack
(A)
Nack
(N)
File Name
See Put File Table
Comma
(,)
File Size
(0000000000)‐(99
99999999)
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
Length
27+
Length
6
Length
6
Stream Data:
This command is executed second. It streams the file data.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg. Ack.
Packet
Start Byte
<STX>
Start Byte
<STX>
Start Byte
<STX>
Command
(p)
Command
(p)
Command
(p)
Stream
(D)
Ack
(A)
Nack
(N)
File Data
Binary Data
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
Length
6+
Length
6
Length
6
Put file table:
Cs1x0.bin – Sends a firmware file.
Cs1x0par.txt – Sends a parameter file.
Measure:
Causes the instrument to initiate and communicate a measurement. This is a
non‐legal for trade mode.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge Packet
Nack
Description
Neg. Ack.
Packet
Start Byte
<STX>
Start Byte
<STX>
Start Byte
<STX>
Command
(M) or (C)
Command
(M)
Command
(M)
Ack
(A)
Nack
(N)
CubiScan OR
Host
(C) or (H)
CubiScan or
Host
(C) or (H)
Location ID
(000000) – (ZZZZZZ)
Measure or
Zero
(M) or (Z)
Comma
(,)
Length
(L000.0) – (L999.9)
Comma
(,)
Width
(W000.0) – (W999.9)
Comma
(,)
Height
(H000.0) – (H999.9)