Communications Protocol
Barcode Port
CubiScan 110-T
56
The following table shows the USB 2.0 type B connector pin assignments.
It is configured as a communications device class (or USB CDC). The device
attaches, on the USB side, to a RS-232 communications line and the
computer operating system. This makes the USB device appear as a
traditional RS-232 port.
Barcode Port
The Scanner/Barcode port can be enabled in the menus of the main
controller. The Expanded Communication Protocol is utilized when it is
enabled.
The barcode reader should be configured to send the barcode with a suffix
of <LF>.The CubiScan uses the “End of Barcode” character as an indicator
that the barcode has been scanned in its entirety. Scanned barcodes are
transmitted with the next “Measure” command. If two barcodes are
scanned and then a measurement is taken, the most recent barcode will be
transmitted. If one barcode is scanned and then two measurements are
taken, the first measurement will contain the barcode while the second
measurement will contain no data for the barcode.
LFT (Sealed)
The CubiScan is placed into LFT mode by moving two sided Switches to the
“ON” position. This seals metrological parameters.
Long Term Storage (Alibi Memory)
The long term storage is always enabled. A SD card must be installed in the
main controller. This causes the CubiScan to write all measurement
USB 2.0 type B Connector Pin Assignments
Pin
Name
Cable
Color
Description
1
VCC
Red
+5 VDC
2
D-
White
Data -
3
D+
Green
Data +
4
GND
Black
Ground