Troubleshooting
Diagnostics
CubiScan 110-T
51
2. The diagnostic menu is displayed at the bottom of the screen. Select the
Sensors
option if it is not already selected.
Sensor diagnostic screens one through four display information for the left,
right, top, and front sensor. From the example shown you can view the left
sensor diagnostic values. To view the values for the right and top sensors,
tap the
[>]
button.
DBW
This field displays the Distance to the Back Wall (DBW).
Pulses
This field displays the number of pulses the sensor has received.
Gain
This field displays the gain step distance and affects the sensor sensitivity.
Lft
This field displays the distance in inches of how far sound waves travel
from the sensor before they are interrupted. (Lft stands for left sensor, Rgt
stands for right sensor, and Top stands for top sensor.)
CPI
This field displays the Counts Per Inch (CPI).
Blank
This field displays the blanking zone, which is the dead zone in front of the
sensor.
Delay
This field displays the internal timing parameter in milliseconds.
TMPR
This field displays the internal temperature of the sensor.
Figure 51
First Sensor Diagnostic Screen