Communications Protocol
CubiScan 110-T Command Set
CubiScan 110-T
65
Test:
Causes the instrument to respond back through the interface. This is used to
determine if communication is active.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg. Ack.
Packet
Start Byte
<STX>
Start Byte
<STX>
Start Byte
<STX>
Command
(T)
Command
(T)
Command
(T)
Ack
(A)
Nack
(N)
Identifier
(00) – (99)
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
Length
5
Length
8
Length
6
Identifiers
00 CubiScan OK
Units:
Causes the instrument to communicate the current unit settings, dimensional factor
and location ID.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg. Ack.
Packet
Start Byte
<STX>
Start Byte
<STX>
Start Byte
<STX>
Command
(U)
Command
(U)
Command
(U)
Ack
(A)
Nack
(N)
Dimension
Unit
(E) or (M)
Weight Unit
(E) or (M)
Factor Type
(D) or (I)
Dimensional
Factor
(0001) – (9999)
City Code
(000000) – (ZZZZZZ)
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
End Bytes
<ETX><CR><LF>
Length
5
Length
19
Length
6
Values – CubiScan 110T, 150T:
Causes the instrument to communicate various
internal values.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg. Ack. Packet
Start Byte
<STX>
Start Byte
<STX>
Start Byte
<STX>
Command
(V)
Command
(V)
Command
(V)
Ack
(A)
Nack
(N)
Len1 DBW