Corporate
800.882.8854
86
Theory of Operation/Product Description
PurWater 4 & 8 Gram Ozone Manual
4 Gram Ozone System (CD12/AD)
8 Gram Ozone System (2- CD12/AD units)
The feed gas (Oxygen) is drawn through the ozone generator by the vacuum created at the ozone injector
rather than by the pressure from the air preparation system compressors.
As the feed gas enters the thermally-
protected reaction chambers inside the ozone generator, some of the oxygen molecules are split while
passing through the high voltage electrical field (the “corona”), forming single oxygen atoms (O
1
). These
oxygen atoms then recombine with other oxygen molecules in the air stream, forming ozone.
The Ozone Generators are designed to produce Ozone for 30 minutes after first being powered up and then
requires a 30 minute cool down period. This cycle is controlled by the Reclaim System’s PLC and the status of
whether the Ozone is “On or Off” can be read on the display of the HMI screen, located on the Reclaim’s Main
Control Box.
Many safety features are also built in, including main power fuses, thermal protection, cover safety switch,
and back flow prevention.