System Troubleshooting - Major Fault - “No Pump psi”
A “No Pump psi Fault”
will automatically put the
system in fresh water
bypass and the Reclaim
will run using fresh water
when a wash activation
signal is present.
Once the operator touches
the yellow fault button, the
screen will go to the lower
screen filled with text.
A system with this fault
can not be run until the
fault is corrected. If this
fault occurs when priming
a brand new system it
may take a few iterations
to get all the air out of the
suction line. Make certain
that none of the suction
line is higher than the
stariner basket inlet.
If this fault occurs on an
older system, check the
strainer basket lid oring
and sealing surface. The
suction line in the tanking
may have a problem with
the foot valve. The flap
may be damaged, it could
be obstructed with an
object such as a plastic
bag or some cloth. It may
need to be removed and
inspected.
Don’t forget the basics!! Make sure the strainer basket is not
clogged! Is it being cleaned weekly as a PM item?
Another issue to consider if there is a problem with the pressure
switch (located on the left side of the control box) or the line that
goes to the pressure switch. Disconnecting the line from the bottom
of the pressure switch & starting the prime sequence should result
in a large stream of water! The pump pressure gauge should read
around 15-25psi in recirculation mode. If the gauge pressure drops
off as it faults the pressure switch is likely okay.
Don’t hesitate to
call for Technical Support at 800-882-8854