Verify Flow Through Underflow (U/F) Valve Weekly
--Verify underflow is not backed up by loosening the front side union while the pump is
running in Auto.
--If a stream of water is coming through the valve - that is all that is required (see pic below)
--If there is no flow, replace the union and force a “Cyclone Flush” from the touch screen then
recheck by removing the union fitting.
--If the Cyclone (U/)F flush did not break the solids free, turn the system to Hand, disconnect the
entire valve by loosening both unions and find out where the blockage is.
--This is important because if solids get trapped behind the valve for too long it can clog up the
cyclones causing untreated water being sent out to the wash. The cyclones can be extremely
difficult to impossible to unclog and may require removal & complete disassembly.
U/F Flush Valve with Water Flowing Through
Pump Out Settling Tanks -- A Minimum Of Every 6 Months
--
Call a local company that pumps out septic tanks and have them pump out the tanks.
--For best results, wash down the tank walls down while empty and pump that out as well.
--Inspect the foot valves and recirculation line. Repair or replace if necessary.
--Refill tanks running in bypass (Hand) or refilling the tanks before turning the system back
to Auto and repriming the system.
Cyclone Flush Procedure (A)
--Look at the Touch Screen and see if a grey
“Flush Cyclones” box is present in the lower
right of the screen.
--If present, activate the flush by touching the
grey box
Cyclone Flush Procedure (B)
--Look at the Touch Screen and see if a grey
box is present in the lower right of the screen.
--If not present, touch the Reclaim System
graphic on the Touch Screen and the grey
“Flush Cyclones” box will appear.
--Activate the flush by touching the grey box