Maintenance
Monthly Procedures
Ozone Generator
• Cooling Fan Operation: Check to make sure the cooling fan mounted on the bottom panel of the
ozone generator is operating. If not, refer to the Troubleshooting Guide.
• Cooling Fan Filters: Check the cooling fan filter element mounted on the fan assembly located at the
bottom panel of the ozone generator and clean as required. Operating conditions in the equipment area
will dictate the frequency required for this procedure. Remove the filter element and clean with soap and
water, drying them completely before re-installing (see Figure 13).
Ozone Generator Cooling Fan Assembly
Figure 13
Fan
Ozone Generator Bottom Panel
Finger Guard
Fan Filter Element
Fan Filter Grill
Annual Procedures
CD12/AD
• Every 12-18 months the CD12/AD will need to be rebuilt. Contact PurWater regarding our rebuild/exchange
program. The rebuild will consist of replacing the Air Preparation media and replacing the ozone cells.