Check Touch Screen Daily
If possible, to avoid running in bypass mode for prolonged periods of time without
realizing it, take a quick look at the HMI touch screen:
--Is a normal “Auto” Screen on the display?
--Is a fault present on the screen? See message & fault in yellow background. If so - follow
the screen prompts for resolution. If unable to resolve the issue go to the troubleshooting
section for a better understanding of the cause and solution for the fault message.
Typical Fault Screen
Normal Screen Indicates Reclaim in Bypass
Check Pump Pressure Gauge Weekly
• The pump pressure gauge should show pressure when the motor is running.
• This pressure will vary. If a wash activation is on it will be much higher than when the
Reclaim is running at recirculation speed and the wash is idle.
- In the low frequency recirculation mode the pressure should be about 15-25 psig
- At higher pump speeds, when there is an activation signal from the car wash, the
pump pressure may read as high as 50-55 psig.
• If there is no pressure please refer to the Troubleshooting Section.
Pump pressure gauge
Typical Pressure During Recirculation Typical Pressure During Wash Activation
System Maintenance