1.4
Proper
Use
•
The
DULCOTROL
®
measuring/control stations are only designed to measure or control liquid
metering media in accordance with the Identcode feature specifi ed on the rating plate of the
measuring/control station.
•
The
DULCOTROL
®
measuring/control stations are not designed to meter or control gaseous or
solid media.
•
The
DULCOTROL
®
measuring/control stations may only be used in compliance with the
technical data and specifi cations stated in these operating instructions and the operating
instructions of the individual components!
• You are obliged to observe the information in the operating instructions on the various life
phases of the DULCOTROL
®
measuring/control stations (such as assembly, installation, …)!
•
The
DULCOTROL
®
measuring/control stations may not be used for applications in the open.
• All other uses or modifi cations of the DULCOTROL
®
measuring/control stations require the
prior written consent of ProMinent Dosiertechnik GmbH, Heidelberg, Germany.
•
The
DULCOTROL
®
measuring/control stations may only be operated by suffi ciently qualifi ed
personnel (see table below). The operator of the DULCOTROL
®
measuring/control station is
responsible for the qualifi cation of the personnel.
1.5
Qualifi cation of the Personnel
Safety Chapter / Storage and Transport
Tasks
Qualifi cation
Mounting, installation, hydraulical
Qualifi ed employee
Installation, electrical
Qualifi ed employee
Commissioning
Trained user
Maintenance
Trained person
Troubleshooting
Qualifi ed employee
Disposal
Trained person
2
Storage and Transport
CAUTION
• Before storing or transporting, the DULCOTROL
®
measuring/control stations must be
free from metering media and water!
• Only transport and store the DULCOTROL
®
measuring/control station in its original
packaging!
• Protect the packaged DULCOTROL
®
measuring/control station also against moisture
and exposure to chemicals and mechanical infl uences!
• Please also read the operating instructions of the controllers and fi ttings and any other
existing assemblies such as sensors, sample water pump … !
Environmental conditions for storage and transport of
measuring panel without sensors
Temperature
5 ... 50 °C
Relative humidity
< 95 % relative humidity, non-condensing
Sensors
Store and transport the sensors within the sensor-specifi c parameters. For information on the
individual cases, please see the documentation for the individual sensors.
NOTE
If the DULCOTROL
®
measuring/control stations are stored together with the sensors as an
assembly, the storage and transport conditions should be adjusted to the component part
with the lowest resistance to external infl uences!