Command ‘c’— Sub-command Index 02:
Stop Stream(s)
This sub-command is used to stop (or temporarily suspend) the delivery of any previously
started host stream in a module, one at a time or all together, whether the stream was
“continuous” or “limited.” The sub-command’s format is:
Command
“
c 02
st
”
‘c’ is the
command
letter
‘02’ is the sub-command index (‘
ii
’) for
Stop Stream
‘
st
’ is the stream
id
digit (single stream 1, 2, or 3, or 0=
all streams
)
NOTE: all parameters are separated by a
space
.
Response
“
A
”
‘A’ is the
acknowledge
letter
Autonomous
Packet
command stops generation of autonomous packets from the requested
stream(s).
Description:
This sub-command stops the current “run” of a particular specified host stream
(
st
=1-3), or stops the current “run” of “all configured” host streams with a single
command
(
st
=0).
Any stopped stream may be resumed (i.e., restarted) with the
Start Stream
sub-
command as long as that stream remains defined in the module and any limited
sequence count has not yet expired. The
Clear Stream
sub-command may be
used to undefine a stream. Any continuous stream or unexpired limited stream
that is restarted continues generating new sequence numbers (i.e., at the count
where it left off when stopped). However, the stream must be reconfigured with
the
Configure a Host Delivery Stream
sub-command (00) before it restarts with
sequence count =1. Any expired limited
stream must be reconfigured to restart
at all.
Example:
●
Stop all the streams configured in the previous example:
“
c 02 0
”
Read
response:
“A”