SERIES-300 S / SCS / SIP
PAG OERLIKON AG
CALIBRATION INSTRUCTIONS
D 04.07
14. Final control
- Initial loading
- Corner loading
- Linearity
15. S-correction
Description:
By each linearisation of the balance the S-correction is going to be lost in order to allow a correct
adjustment to the linearity of the balance range. Therefore after each linearisation the S-correction has
to be checked and rectified if necessary.
It should be
never
more digits corrected as show below, otherwise the balance needs again a
mechanical check (dismantle / assemble the balance again and if necessary change the flexures).
max. correction allowance
Sa, Sb
--> +/- 7 digits
Sc, Sd
--> +/- 3 digits
1
Calibration of the internal reference weight for gauged balances
- Switch on the balance
- Remove seal (if present) on the right-hand side of the housing's top
- Undo the screw (1) and remove
- Press the gauge switch (1)
- The calibration cycle starts automatically at page D 04.05
- At the end of calibration of the internal reference weight, assemble the screw (1) again
Summary of Contents for 300 SCS series
Page 1: ...PAG OERLIKON AG The Balance of Quality SERVICE MANUAL SERIES 300 S 300 SCS 300 SIP...
Page 135: ...PAG OERLIKON AG SERIES 300 S SCS SIP MAIN BOARD 300 7218 010 HAUPTPRINT 300 7218 010 C 01 03...
Page 150: ...PAG OERLIKON AG SERIES 300 S SCS SIP MAIN BOARD 300 7235 010 HAUPTPRINT 300 7235 010 C 02 06...
Page 159: ...PAG OERLIKON AG SERIES 300 S SIP ANALOGUE BOARD 300 7219 010 ANALOGPRINT 300 7219 010 C 03 01...
Page 162: ...PAG OERLIKON AG SERIES 300 SCS ANALOGUE BOARD 300 7238 010 ANALOGPRINT 300 7238 010 C 04 01...
Page 194: ...SERIES 300 S SCS SIP PAG OERLIKON AG CALIBRATION INSTRUCTIONS D 04 11 Final control...