05/2020

334MSB440

440 lb.

Eye Level Mechanical 

Physicians Scale w/ Height Rod

USER MANUAL

Summary of Contents for 334MSB440

Page 1: ...05 2020 334MSB440 440 lb Eye Level Mechanical Physicians Scale w Height Rod USER MANUAL ...

Page 2: ...t Beam Poise Weights Small Upper Large Lower Height Rod Pillar Frame Platform Scale Base Rear Wheels SPECIFICATIONS GENERAL INFORMATION TABLE OF CONTENTS 1 334MSB440 MAXIMUM CAPACITY 440 lb 200kg WEIGHT GRADUATION 0 25 lb 0 1kg HEIGHT MEASUREMENT RANGE 24 85 50 212cm HEIGHT GRADUATION 0 125 0 1cm PLATFORM SIZE 14 75 x 10 75 TOWER HEIGHT 58 4 General Information 1 Unpacking Setup 2 Packing List 2 T...

Page 3: ...beam faces the scale base 4 Using a Phillips screwdriver screw in the eight bolts and washers to secure the pillar to scale base as shown in Fig 3 Pillar Steel Connection Rod Height Rod Wheels Philips Head Screwdriver Not Supplied Wrench Included UNPACKING SETUP PACKING LIST TOOLS REQUIRED INSTALLATION PROCEDURE 5 Lay the scale on a table Remove and discard the shipping tie wrap wires on the under...

Page 4: ...gh properly If the scale is slightly tipped to one side the linkage can be seen by looking up underneath the top weigh beam 8 Place the scale gently back on the floor 6 Insert the wrench included into the small hole in front of the steel rod and pull the rod hook with the wrench to connect it to the scale base as shown in Fig 5 The steel rod is located inside the scale pillar Once the pillar is at...

Page 5: ...r the height rod press the red button at the top of the height rod 1 Align the angle iron of the wheel base to the scale platform as shown in Fig 8 2 Use the screws and washers that are included to affix the wheel assembly to the platform Adjust the angle iron at a level position and then tighten screws 3 When moving the scale hold the two side faces of the pillar to keep the front side of the pla...

Page 6: ...in the eye loop area Release the scale pointer and let it rise freely up or down 3 If the pointer doesn t remain centered turn the zero adjustment screw shown in Fig 9 using a flathead screwdriver until the pointer remains centered within the eye loop After assembly the scale must be zeroed prior to use ZERO ADJUSTMENT Zero Adjustment Screw Weigh Beam Scale Pointer Eye Loop Area Fig 9 ...

Page 7: ...e linkage must be free floating in order for the scale to weigh properly If the scale is slightly tipped to one side the linkage can be seen by looking up underneath the top weigh beam Platform rocks excessively Ensure scale is sitting on a level surface When you push down on any corner of the platform you should not feel any significant rocking Beam does not move at all during weighing Weights ar...