Pratt & Whitney Rzeszów S.A.
MAINTENANCE MANUAL
PZL-10W ENGINE
1992.08.28
72-02-00
Page 117
Export Control Classification: PL/UE 9E999
C.
Fuel-Control System.
(1)
Defective system operation during engine starting.
Possible causes and schematic procedure: see item A.
(2)
Power turbine rotational speed ( N2 ) governor does not operate.
(a)
Possible causes: fuel-metering pump electrohydraulic valve slide is blocked in hand control position; N2
pick-up is damaged in the control circuit; inlet air temperature (OAT) pick-up is damaged; electric
connection failures between the pick-ups and electronic limiter unit and fuel-metering servovalve;
electronic limiter unit defective; fuel- metering pump out of order.
(b)
Schematic procedure: