1.92
9850060 R02 - 2020-2021 850 AXYS™ Long Track Snowmobile Service Manual
© Copyright Polaris Inc.
DIGITAL WRENCH – DATA TRIGGER
(FREEZE FRAME)
Clicking on the Data Trigger (Freeze Frame) button will
allow the user to enter a data item or trouble code (DTC)
to activate a freeze frame recording.
DIGITAL WRENCH DATA TRIGGER DISPLAY
REF.
DESCRIPTION
q
Select a data item to set the trigger
w
Select a trouble code (DTC) to set the trigger
e
List of either data items (if data item is selected
as the trigger) or trouble codes (if trouble code is
selected as the trigger)
r
Enable or reset trigger recording
In the example shown below, TPS Volts was selected as
the Data Item Trigger.
Digital Wrench prompts the user to select the
Comparison
t
and the Value In this case, the
Comparison was set to “Greater Than” and the Value
was set to 3.50 volts.
After the values are selected, the user then clicks on Arm
Trigger.
When the trigger is set, Digital Wrench will revert to the
Data List display and freeze the data values when the
TPS voltage is greater than 3.50 volts.